ILRS Site and System Information Form International Laser Ranging Service 0. Form Prepared by (Full Name) : Stefan Riepl Preparer E-mail : riepl@wettzell.ifag.de Date Prepared : 2002-05-09 Report Type : UPDATE Site Log Format Version : 2.0 Site Log Revision : 1. Identification of the Ranging System Reference Point (SRP) Site Name : Wettzell IERS DOMES Number : 14201M200 CDP Pad ID : 7594 Subnetwork : EUROLAS Description : MONUMENT Monument Description : PLATE Monument Inscription : NONE Mark Description : NAIL Date Installed : 1997-01-01 Date Removed : Geologic Characteristic : BEDROCK/CLAY Additional Information : System will be shipped to Concepcio/Chile : by the end of 2001 2. Site Location Information City or Town : Koetzting State or Province : Bavaria Country : Germany Tectonic Plate : Eurasian Local Time (UTC +/- hours) : Approximate Position X coordinate [m]: 4075595.9 Y coordinate [m]: 931733.1 Z coordinate [m]: 4801568.4 Latitude [deg]: 49.1443 N Longitude [deg]: 12.8773 E Elevation [m]: 658.417 Survey Method : Date Measured : Additional Information : 3. General System Information 3.01 System Name : TIGO 4-Character Code : WETT CDP System Number : 79 CDP Occupation Number : 01 Eccentricity to SRP (if Not Identical With SRP) North [m]: -0.100 +- 0.001 East [m]: -0.055 +- 0.001 Up [m]: 1.467 +- 0.001 Date Measured : 1998-01-01 Date Installed : 1998-01-01 Date Removed : Additional Information : system eccentricities in original : site log wett_20001004.log were wrong. : (i.e. from the optical axes to the : marker versus the marker to the : optical axes) 4. Telescope Information 4.01 Receiving Telescope Type : folded galilean Aperture [m]: 0.5 Mount : AZ-EL Date Installed : Date Removed : Xmitting Telescope Type : folded galilean Aperture [m]: 0.1 Date Installed : Date Removed : Tracking Camera Type : CCD/TV Model : PROXICAM Manufacturer : PROXICAM Field of View [deg]: 0.016 Minimum Magnitude [mag]: 8 Date Installed : Date Removed : Transmit/Receive Path : COMMON COUDE Transmit/Receive Switch : N.A. Max Slew Rate Az [deg/s]: 10 Max Slew Rate El [deg/s]: 10 Max Used Tracking Rate Az : 10 Max Used Tracking Rate El : 10 Telescope Shelter : DOME Daylight Filter Type : AIR SPACED ETALON Dayl. Filt. Bandwidth [nm]: 0.1 Adjustable Attenuation : TRANSMIT Adjustable Field of View : Transmit Efficiency : 0.95 Receive Efficiency : 0.9 Date Installed : 1998-01-01 Date Removed : Additional Information : Transmit/Receive Switch: `SHARED APERTURE` 5. Laser System Information 5.01 Laser Type : TI:SAP Model : Manufacturer : Number of Amplifiers : 3 Primary Wavelength [nm]: 847 Primary Maximum Energy [mJ]: 60 Secondary Wavelength [nm]: 423.5 Secondary Max. Energy [mJ]: 30 Xmit Energy Adjustable : YES Additional Information : Pulse Width (FWHM) [ps]: 80 Max. Repetition Rate [Hz]: 10 Fullw. Beam Divergence ["]: 2 - 60 Theoretical Beam Div : Measured Beam Div : Method Used : Additional Information : Final Beam Diameter [m]: 0.1 Eyesafe : NO Eyesafe Standard : DIN VDE 0837 (IEC 825) Polarization on Exit : Laser Fire Control : Laser Energy Monitor : Start Diode Type : Manufactorer : Model : Quantum Efficiency [%]: Rise/Fall Time [ps]: Date Installed : Date Removed : Signal Processing : Manufacturer : Model : Date Installed : Date Removed : Additional Information : Date Installed : 1998-01-01 Date Removed : Additional Information : 1 regenerative/ 2 linear multipath : amplifiers : Start Detector Specifications : Wavelength : 847 nm : Type : APD linear mode : Manufacturer : K.H.Haufe : Rise Time : < 100 ps : Jitter : 20 ps : Expose mode : focused : Signal Processing : CFD : Date Installed : 2001-01-31 : : Pulse Width: 80/56 6. Receiver System 6.01.01 Primary Chain Wavelength [nm]: 423.5 Detector Type : CSPAD Manufacturer : PESO Consulting Model : 1 Quantum Efficiency [%]: 10 Nominal Gain : 1e9 Rise Time [ps]: 100 Jitter (Single PE)[ps]: 80 Field of View Diam ["]: 60 Date Installed : 1998-01-01 Date Removed : Amplifier Type : Manufacturer : Model : Gain : Bandwidth : Date Installed : Date Removed : Additional Information: Signal Processing : Time Walk Compensated Manufacturer : Graz Model : V01 Date Installed : 1998-01-01 Date Removed : Amplitude Measurement : YES Return-Rate Controlled: YES Mode of Operation : SINGLE/FEW PHOTON Additional Information: Time of Flight Observ. : EVENT Manufacturer : PESO Consulting Model : PET 4 Resolution [ps]: 1.22 Precision [ps]: 7 Date Installed : 2000-07-01 Date Removed : Additional Information : Rise Time: < 100 6.01.02 Primary Chain Wavelength [nm]: 423.5 Detector Type : CSPAD Manufacturer : PESO Consulting Model : 1 Quantum Efficiency [%]: 10 Nominal Gain : 1e9 Rise Time [ps]: 100 Jitter (Single PE)[ps]: 60 Field of View Diam ["]: 10 Date Installed : 1998-01-01 Date Removed : Amplifier Type : Manufacturer : Model : Gain : Bandwidth : Date Installed : Date Removed : Additional Information: Signal Processing : Time Walk Compensated Manufacturer : Graz Model : V01 Date Installed : 1998-01-01 Date Removed : Amplitude Measurement : YES Return-Rate Controlled: YES Mode of Operation : SINGLE/FEW PHOTON Additional Information: Time of Flight Observ. : INTERVAL Manufacturer : Stanford Model : 620 Resolution [ps]: 4 Precision [ps]: 30 Date Installed : 1998-01-01 Date Removed : 2000-07-01 Additional Information : Rise Time < 100 6.01.03 Primary Chain Wavelength [nm]: 423.5 Detector Type : PMT Manufacturer : Hamamatsu Model : H7421-50 Quantum Efficiency [%]: 15 Nominal Gain : 1e9 Rise Time [ps]: 1000 Jitter (Single PE)[ps]: 60 Field of View Diam ["]: 60 Date Installed : 2001-01-31 Date Removed : Amplifier Type : Manufacturer : Model : Gain : Bandwidth : Date Installed : Date Removed : Additional Information: Signal Processing : CFD Manufacturer : ORTEC Model : QUAD CFD Date Installed : 2001-01-31 Date Removed : Amplitude Measurement : NO Return-Rate Controlled: YES Mode of Operation : SINGLE PHOTON Additional Information: Time of Flight Observ. : EVENT Manufacturer : PESO Consulting Model : PET 4 Resolution [ps]: 1.22 Precision [ps]: 3 Date Installed : 2000-07-01 Date Removed : Additional Information : Rise Time: < 1000 : Precision: <3 6.01.04 Primary Chain Wavelength [nm]: 423.5 Detector Type : APD Manufacturer : Lutz Beyer Model : SP114 Quantum Efficiency [%]: 50 Nominal Gain : 1e9 Rise Time [ps]: 100 Jitter (Single PE)[ps]: 60 Field of View Diam ["]: 60 Date Installed : 2001-01-31 Date Removed : Amplifier Type : Manufacturer : Model : Gain : Bandwidth : Date Installed : Date Removed : Additional Information: Signal Processing : None Manufacturer : Model : Date Installed : Date Removed : Amplitude Measurement : NO Return-Rate Controlled: YES Mode of Operation : SINGLE PHOTON Additional Information: Time of Flight Observ. : EVENT Manufacturer : PESO Consulting Model : PET 4 Resolution [ps]: 1.22 Precision [ps]: 3 Date Installed : 2000-07-01 Date Removed : Additional Information : Rise Time: < 100 : Precision: <3 6.02.01 Secondary Chain Wavelength [nm]: 847.0 Detector Type : CSPAD Manufacturer : PESO Consulting Model : 1 Quantum Efficiency [%]: 10 Nominal Gain : 1e9 Rise Time [ps]: 100 Jitter (Single PE)[ps]: 60 Field of View Diam ["]: 60 Date Installed : 2000-07-01 Date Removed : Amplifier Type : Manufacturer : Model : Gain : Bandwidth : Date Installed : Date Removed : Additional Information: Signal Processing : Time Walk Compensated Manufacturer : Graz Model : V01 Date Installed : 2000-07-01 Date Removed : Amplitude Measurement : YES Return-Rate Controlled: YES Mode of Operation : SINGLE/FEW PHOTON Additional Information: Time of Flight Observ. : EVENT Manufacturer : PESO Consulting Model : PET 4 Resolution [ps]: 1.22 Precision [ps]: 3 Date Installed : 2000-07-01 Date Removed : Additional Information : Precision: <3 6.03.01 Tertiary Chain Wavelength [nm]: Detector Type : Manufacturer : Model : Quantum Efficiency [%]: Nominal Gain : Rise Time [ps]: Jitter (Single PE)[ps]: Field of View Diam ["]: Date Installed : Date Removed : Amplifier Type : Manufacturer : Model : Gain : Bandwidth : Date Installed : Date Removed : Additional Information: Signal Processing : Manufacturer : Model : Date Installed : Date Removed : Amplitude Measurement : Return-Rate Controlled: Mode of Operation : Additional Information: Time of Flight Observ. : Manufacturer : Model : Resolution [ps]: Precision [ps]: Date Installed : Date Removed : Additional Information : 7. Tracking Capabilities 7.01 Satellites Very Low Alt (<400 km) : YES Low Altitude (400-2000) : YES LAGEOS/LARES : YES GLONASS : YES Etalon : YES GNSS : YES Geosynchronous : Moon : NO Ave. Pass Switch Time [s]: 60 Average values for LAGEOS Single Shot RMS [mm]: 24 # of Obs per NP : 20 Use of Semi-trains : NO # of Semi-train Tracks : N.A. Range Gate Width [ns]: 200 Beam Pointing Accuracy ["]: 5 Angle Encoder Resolution["]: 0.5 Min. Tracking Elev. [deg]: 20 Laser Polarization @emitter: Operation Months per Year : 0 Days per Week : 0 Hours per Day : 0 Staff per Shift : N.A. System Shared With : NOTHING Time Allocated to SLR [%]: 100 Remotely Controllable : NO Tracking Restrictions Go/No-go flag : Satellite Verification : Date Verified : Maximum elevation : Satellite Verification : Date Verified : Pass segments : Satellite Verification : Date Verified : Schedule segments : Satellite Verification : Date Verified : Maximum laser power limit: Satellite Verification : Date Verified : Date First Applicable : Date Last Applicable : Additional Information : 8. Calibration 8.01 Calibration Type : PRE+POST Target Location : INTERNAL Target Type : FLAT SURFACE Target Structure : FLIP MIRROR INSIDE TELESCOPE Number of Targets : Target Distance(s) [m]: -2.351 Date Measured : 1998-01-01 Accuracy [mm]: 1 Verification : Return-Rate Controlled : YES Eye-Safe Method : Additional Information : Mode of Operation : SINGLE PHOTON Calibration performed : 45 Single Shot RMS [mm]: 15 Edit Criterion 1st Chain : ITERATIVE 2.5 SIGMA Edit Criterion 2nd Chain : ITERATIVE 2.5 SIGMA Application of Cal Data : LINEAR FIT Date Installed : 1998-01-01 Date Removed : Additional Information : 9. Time and Frequency Standards 9.01.01 Frequency Standard Type : Cesium Model : 5071A Manufacturer : HP Short Term Stab. [e-12]: 10 Long Term Stab. [e-12]: 0.05 Time Reference : GPS Synchronization : GPS Epoch Accuracy [ns]: 10 Date Installed : 1997-01-01 Date Removed : Additional Information : 9.02.01 GNSS Timing Rcvr Model : 9390 Manufacturer : Datum Date Installed : 1997-01-01 Date Removed : Additional Information : 9.03.01 One-way System Calibration Date performed : Direction Calibrated : Additional Information : 10. Preprocessing Information 10.01 On-site NP Generation : YES Data Screening : AUTOMATIC (TIMEBIAS-MODEL) + SOLVE Return-Rate Rejection : Edit Criterion 1st Chain : 2.5 SIGMA Edit Criterion 2nd Chain : 2.5 SIGMA Upload interval : AFTER EACH PASS Date First Applicable : 1997-01-01 HH:MM UT Date Last Applicable : Additional Information : 11. Aircraft Detection 11.01 Detection Type : RADAR Manufacturer/Provider : Automatic Laser Shutoff : Alarms Recorded : Hazard Distance [km]: Date Installed : 1997-01-01 Date Removed : Additional Information : 12. Meteorological Instrumentation 12.01.01 Pressure Sensor Model : Digiquartz 740-16B Manufacturer : Paroscientific Recording Interval : EVERY 1 MINUTE Accuracy [mbar]: 0.1 Height Diff to SRP [m]: 0 Distance from SRP [m]: Date Installed : 1997-01-01 HH:MM UT Calibration Interval : YEARLY Date Removed : Additional Information : 12.02.01 Temp Sensor Model : 809 Manufacturer : Lambrecht Recording Interval : EVERY 1 MINUTE Accuracy [deg C]: 0.3 Date Installed : 1997-01-01 HH:MM UT Calibration Interval : MONTHLY Date Removed : Additional Information : 12.03.01 Humidity Sensor Model : 809 Manufacturer : Lambrecht Recording Interval : EVERY 1 MINUTE Accuracy [% rel h]: 2.5 Date Installed : 1997-01-01 HH:MM UT Calibration Interval : MONTHLY Date Removed : Additional Information : 13. Local Ties, Eccentricities, and Collocation Information 13.01 Collocated Permanent Geodetic Systems 13.01.01.01 GNSS : IGS+EUREF Date Installed : 1995-02-09 Date Removed : Additional Info : another IGS site : installed 1997-02-06 13.01.01.02 GNSS : IGLOS Date Installed : 1999-02-01 Date Removed : Additional Info : 13.01.02.01 DORIS : NO Date Installed : Date Removed : Additional Info : 13.01.03.01 PRARE : YES Date Installed : 1997-01-20 Date Removed : 1997-02-03 Additional Info : Other PRARE installations : 1996-03-26 to 1996-05-21 : 1996-12-11 to 1996-12-23 : 1997-01-02 to 1997-01-12 13.01.04.01 VLBI : YES Date Installed : 1983-01-01 Date Removed : Additional Info : 13.01.05.01 Gravimeter : SUPERCONDUCTING Date Installed : 1998-11-01 Date Removed : Additional Info : 13.01.06.01 Other SLR : Date Installed : Date Removed : Additional Info : 13.02.01.01 Local Ties from the SRP to Other Monuments or Systems on Site Monument Name : VLBI, TIGO Instrumentation Type : VLBI Instrumentation Status : MOBILE DOMES Number : 14201S100 CDP Number : 7593 Differential Components (ITRS) dx [m]: -23.210 +- 0.015 dy [m]: 22.032 +- 0.005 dz [m]: 15.951 +- 0.018 Date Measured : 1997-01-01 Determined by : ITRF97 Date Installed : 1997-01-01 Date Removed : Additional Information : 13.03.01.01 Eccentricities Between Other Monuments on Site From: Monument Name : DOMES Number : CDP Number : To: Monument Name : DOMES Number : CDP Number : Differential Components (ITRS) dx [m]: dy [m]: dz [m]: Date Measured : Determined by : Additional Information : 14. Local Events Possibly Affecting Computed Position 14.01 Date : Event : Additional Information : 15. On-Site, Point of Contact Agency Information Agency : Bundesamt fuer Kartographie und Geodaesie Mailing Address : Sackenriederstr. 25, : D-93444 Koetzting, Germany Website : Primary Contact Contact Name : Stefan Riepl Telephone (primary) : +49 9941 603205 Telephone (secondary) : +49 9941 603333 Fax : +49 9941 603222 E-mail : riepl@wettzell.ifag.de Secondary Contact Contact Name : Armin Boeer Telephone (primary) : +49 9941 603111 Telephone (secondary) : +49 9941 603333 Fax : +49 9941 603222 E-mail : boer@wettzell.ifag.de Tertiary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 16. Responsible Agency (if different from 15.) Agency : Mailing Address : Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 17. More Information URL for More Information : http://www.wettzell.ifag.de Hardcopy on File Site Map : NO Site Diagram : NO Horizon Mask : NO Monument Description : YES Site Pictures : YES Additional Information :