00 ***************************************************************************** 00 * * 00 * This CRD file is available for ILRS data and analysis centre * 00 * validation. It is considered to be compliant with v1.0 of the * 00 * specification. * 00 * * 00 * Company : Electro Optic Systems Pty Limited * 00 * Station : Mt. Stromlo (7825) * 00 * Contact : Chris Moore * 00 * Email : cmoore@eos-aus.com * 00 * * 00 ***************************************************************************** H1 CRD 1 2010 09 10 15 H2 STL3 7825 90 01 4 H3 ers2 9502101 6178 23560 0 1 C0 0 532.0 IDA0 IDA1 IDAD IDAP C1 0 IDA1 Nd-Yag 532.00 60.0 20.800 12.0 10.0 1 C2 0 IDAD CSPAD 532.0 20 15.8 100.0 ECL 12.0 1.0 50 6.0 Auto C3 0 IDAP TrueTime_XLi TrueTime_OCXO MRCS NA 0.2322 H4 1 2010 09 10 13 48 00 2010 09 10 13 53 45 0 0 0 0 1 0 2 0 20 49737.98998492069 921.00 278.95 87.1 0 20 49798.00665161972 921.00 278.95 87.2 0 20 49858.00665162286 921.10 278.95 87.4 0 20 49918.023318323525 921.10 278.95 87.7 0 20 49978.03998491823 921.10 278.85 88.4 0 40 49680 0 IDA0 9082 3108 632.837 168567.00 -5.00 24.00 0.1 -0.4 0.00 2 2 0 50 IDA0 11.20 0.01 -1.02 13.80 0 11 49869.823318321 0.009656325691 IDA0 2 15 13 7.90 0.24 -0.25 0.00 4.41 0 11 49882.823318318 0.009718462568 IDA0 2 15 22 11.30 -0.05 -1.15 -11.00 11.06 0 11 49897.789984921 0.009837406668 IDA0 2 15 36 12.70 0.13 -1.13 -12.30 10.50 0 11 49914.156651616 0.010023428559 IDA0 2 15 26 11.20 0.17 -0.71 -10.90 8.72 0 11 49927.289984923 0.010212858133 IDA0 2 15 23 9.70 0.30 -1.31 -13.30 7.72 0 11 49937.939984917 0.010391260856 IDA0 2 15 12 11.40 -0.26 -1.24 0.00 4.96 0 11 49958.839984919 0.010801233765 IDA0 2 15 18 11.30 -0.09 -1.11 0.00 5.42 0 11 49971.389984917 0.011082469737 IDA0 2 15 21 12.40 -0.06 -1.39 -5.60 4.79 0 11 49983.773318323 0.011383404962 IDA0 2 15 13 9.30 -0.25 -1.10 0.00 4.68 0 H8 00 ***************************************************************************** 00 * * 00 * This CRD file is available for ILRS data and analysis centre * 00 * validation. It is considered to be compliant with v1.0 of the * 00 * specification. * 00 * * 00 * Company : Electro Optic Systems Pty Limited * 00 * Station : Mt. Stromlo (7825) * 00 * Contact : Chris Moore * 00 * Email : cmoore@eos-aus.com * 00 * * 00 ***************************************************************************** H1 CRD 1 2010 09 10 23 H2 STL3 7825 90 01 4 H3 ers2 9502101 6178 23560 0 1 C0 0 532.0 IDA0 IDA1 IDAD IDAP C1 0 IDA1 Nd-Yag 532.00 60.0 20.800 12.0 10.0 1 C2 0 IDAD CSPAD 532.0 20 15.8 100.0 ECL 12.0 1.0 50 6.0 Auto C3 0 IDAP TrueTime_XLi TrueTime_OCXO MRCS NA 0.2322 H4 1 2010 09 10 23 22 32 2010 09 10 23 28 18 0 0 0 0 1 0 2 0 20 84290.37939032051 926.60 282.65 52.4 0 20 84306.4793903204 926.60 282.75 50.3 0 20 84366.49605691926 926.60 282.85 46.9 0 20 84426.4960569226 926.60 282.85 46.1 0 20 84486.5127236224 926.50 282.85 46.5 0 40 84153 0 IDA0 11175 3709 632.827 168558.00 -1.00 22.00 0.1 -0.4 0.00 2 2 0 50 IDA0 12.40 0.05 -0.80 22.70 0 11 84320.196056918 0.008873365962 IDA0 2 15 10 11.30 0.18 -0.87 0.00 2.41 0 11 84336.379390322 0.008819424436 IDA0 2 15 16 8.70 0.13 -0.85 0.00 3.21 0 11 84352.812723614 0.008832887300 IDA0 2 15 10 12.10 -0.18 -0.83 0.00 3.12 0 11 84381.746056918 0.009021832512 IDA0 2 15 20 14.40 0.08 -1.30 16.50 5.04 0 11 84413.646056915 0.009459317485 IDA0 2 15 17 11.20 0.09 -0.53 0.00 3.55 0 11 84424.162723617 0.009651242404 IDA0 2 15 10 10.50 -0.22 -0.50 0.00 1.68 0 11 84442.246056923 0.010030624268 IDA0 2 15 17 16.50 -0.07 -1.29 0.00 4.38 0 11 84456.946056919 0.010380888592 IDA0 2 15 10 12.70 0.24 -1.09 0.00 2.39 0 11 84471.312723619 0.010755643993 IDA0 2 15 12 11.90 -0.00 -1.30 0.00 2.36 0 H8 H9