00 ***************************************************************************** 00 * * 00 * This CRD file is available for ILRS data and analysis centre * 00 * validation. It is considered to be compliant with v1.0 of the * 00 * specification. * 00 * * 00 * Company : Electro Optic Systems Pty Limited * 00 * Station : Mt. Stromlo (7825) * 00 * Contact : Chris Moore * 00 * Email : cmoore@eos-aus.com * 00 * * 00 ***************************************************************************** H1 CRD 1 2010 08 24 08 H2 STL3 7825 90 01 4 H3 jason2 0803201 1025 33105 0 1 C0 0 532.0 IDA0 IDA1 IDAD IDAP C1 0 IDA1 Nd-Yag 532.00 60.0 20.800 12.0 10.0 1 C2 0 IDAD CSPAD 532.0 20 15.8 100.0 ECL 12.0 1.0 50 6.0 Auto C3 0 IDAP TrueTime_XLi TrueTime_OCXO MRCS NA 0.2322 H4 1 2010 08 24 07 55 11 2010 08 24 08 03 49 0 0 0 0 1 0 2 0 20 28549.717037517937 918.10 278.95 63.3 0 20 28609.71703752056 918.20 278.95 63.7 0 20 28669.733704224072 918.30 278.95 64.0 0 20 28729.750370919308 918.20 278.85 64.5 0 20 28789.75037091985 918.20 278.85 64.8 0 20 28849.750370923062 918.30 278.75 64.6 0 20 28909.75382991475 918.20 278.75 64.8 0 20 28969.753829918016 918.30 278.75 64.8 0 40 28512 0 IDA0 16066 6558 632.827 168559.00 -1.00 23.00 0.1 -0.4 0.00 2 2 0 50 IDA0 12.00 -0.07 -1.08 23.70 0 11 28594.633704219 0.010141205230 IDA0 2 15 21 11.30 -0.53 -0.95 -3.40 6.25 0 11 28613.53370422 0.010088776601 IDA0 2 15 30 13.20 -0.06 -1.29 -10.80 9.15 0 11 28645.217037524 0.010142851101 IDA0 2 15 25 13.10 -0.08 -1.20 -11.00 11.85 0 11 28657.333704219 0.010210127242 IDA0 2 15 31 11.00 -0.05 -0.93 -9.20 11.23 0 11 28718.200370919 0.010912138954 IDA0 2 15 18 13.20 0.10 -1.22 0.00 7.29 0 11 28742.867037514 0.011351302058 IDA0 2 15 14 10.10 0.22 -0.58 0.00 8.28 0 11 28773.833704219 0.012008028509 IDA0 2 15 25 12.50 0.16 -1.20 -15.10 9.43 0 11 28821.833704224 0.013216999118 IDA0 2 15 16 12.50 -0.52 -1.18 0.00 10.00 0 H8 00 ***************************************************************************** 00 * * 00 * This CRD file is available for ILRS data and analysis centre * 00 * validation. It is considered to be compliant with v1.0 of the * 00 * specification. * 00 * * 00 * Company : Electro Optic Systems Pty Limited * 00 * Station : Mt. Stromlo (7825) * 00 * Contact : Chris Moore * 00 * Email : cmoore@eos-aus.com * 00 * * 00 ***************************************************************************** H1 CRD 1 2010 08 24 21 H2 STL3 7825 90 01 4 H3 jason2 0803201 1025 33105 0 1 C0 0 532.0 IDA0 IDA1 IDAD IDAP C1 0 IDA1 Nd-Yag 532.00 60.0 20.800 12.0 10.0 1 C2 0 IDAD CSPAD 532.0 20 15.8 100.0 ECL 12.0 1.0 50 6.0 Auto C3 0 IDAP TrueTime_XLi TrueTime_OCXO MRCS NA 0.2322 H4 1 2010 08 24 20 28 18 2010 08 24 20 34 03 0 0 0 0 1 0 2 0 20 73725.46179562073 916.60 274.95 72.1 0 20 73785.48066351954 916.60 274.95 71.7 0 20 73845.49953151753 916.60 274.85 71.4 0 20 73905.51839941667 916.60 274.85 71.4 0 20 73965.51839941987 916.60 274.95 71.7 0 20 74025.53726731897 916.60 274.85 70.7 0 40 73699 0 IDA0 12073 4602 632.824 168556.00 0.00 23.00 0.1 -0.4 0.00 2 2 0 50 IDA0 12.40 -0.05 -0.91 3.00 0 11 73748.707078621 0.014624560407 IDA0 2 15 14 11.50 -0.04 -0.65 0.00 8.19 0 11 73763.461795618 0.014588918119 IDA0 2 15 29 12.40 0.43 -0.76 6.50 10.00 0 11 73774.291984314 0.014579507329 IDA0 2 15 20 14.80 -0.31 -1.22 22.70 8.30 0 11 73791.858022016 0.014594479636 IDA0 2 15 22 10.70 0.01 -1.02 8.90 10.95 0 11 73803.273116419 0.014624218939 IDA0 2 15 12 14.60 -0.27 -1.34 0.00 5.71 0 11 73823.537267322 0.014715492532 IDA0 2 15 10 13.60 0.34 -1.08 0.00 11.63 0 11 73852.405191817 0.014928779249 IDA0 2 15 16 14.40 -0.40 -1.33 0.00 9.04 0 11 73884.782550318 0.015279483396 IDA0 2 15 10 10.70 0.67 -0.42 0.00 5.18 0 11 73913.971229619 0.015690194282 IDA0 2 15 16 13.20 -0.71 -0.82 0.00 8.74 0 11 73926.688210718 0.015895336836 IDA0 2 15 16 11.20 0.03 -0.48 0.00 9.25 0 11 73939.329720114 0.016114153861 IDA0 2 15 10 8.40 -0.35 -1.07 0.00 6.67 0 11 73988.216512613 0.017088609561 IDA0 2 15 14 11.30 -0.65 -0.27 0.00 6.03 0 11 74004.612739016 0.017456801671 IDA0 2 15 16 11.10 -0.01 -0.84 0.00 7.73 0 H8 H9