Date: | 2012-09-11 15:14:58 | |
Sender: | Horst Mueller <mueller@dgfi.badw.de> | |
Subject: | [RapidServiceMail] No.36: Simeiz 1.2 m range bias | |
Content: | ******************************************************************************** ILRS/AWG Rapid Service Mail 2012-09-11 15:15:06 UTC Message No. 36 ********************************************************************************Dear colleagues in Simeiz, the Lageos2 data delivered since Sep. 6 seems to have a significant range bias, see below: Station year mm dd hh mm range-bias sigma prec.est. no of edit. time-bias sigma [cm] [cm] [cm] observations [microsec.] Simeiz 2012 9 6 19:07 : -126.11 4.24 6.01 10 0 Simeiz 2012 9 7 21:11 : -121.39 4.47 5.94 8 0 Simeiz 2012 9 8 19:21 : -126.25 4.38 9.26 8 0 Simeiz 2012 9 8 23:15 : -127.13 5.59 10.27 11 0 Simeiz 2012 9 9 17:42 : -124.67 11.02 6.59 6 0 Simeiz 2012 9 9 21:35 : -123.77 6.03 6.19 4 0 Biases for LEOs are smaller (around 40 cm) but also significant. Please check your system. Best regards Horst Mueller ******************************************************************************** |