Dear Colleagues,

MOBLAS 6 Became inoperative during the past weekend, we discovered on
arrival yesterday morning (October 4) that MOB6 had a timing problem,
loss of our Truetime Receiver operation as well as the 5085A Standby
Supply Unit.

The problem was traced to batteries inside the 5085A Standby Supply
Unit.

After replacing the faulty batteries and resetting the Truetime Receiver
XL-DC and Station Time Code Generator 8366B we regained normal
operations during the afternoon.

We regret any inconveniences caused by this failure.