Date: | 2014-12-12 10:26:18 | |
Sender: | ”Luis Manuel Cortina Moncayo” <lmcortina@roa.es> | |
Subject: | [SLR-Mail] No.2286: 7824 SFEL: Calibration distance issue | |
Author: | Manuel Quijano Macias | |
Content: | Author: Manuel Quijano Macias / SFEL station Dear colleagues: San Fernando SLR station (SFEL 7824) uploaded data files since Jun 12 to Aug 8, 2014 are affected by an error due a wrong measurement in the distance from the telescope cross axis to the calibration target. The reported distance was 444 cm while the true one is 451 cm. A +233 ps biass should be applied for this period When trying to fix the error we made a new one affecting the data files uploaded since Aug 8, because we had not into account the calibration target angular displacement. So the used distance was 462 cm, but not the above mentioned 451. In this case the biass to apply must be -367ps. We have modified paragraph 8.04 in the SFEL log file to clarify this problem. Since this night, 02/12/2014 00:00:00.00, we´ll apply the new value 451 cm. We apologize for the inconveniences caused by these errors. Best regards ========================================== Manuel Quijano Macias Real Instituto y Observatorio de la Armada mquijano@roa.es C/ Cecilio Pujazón s/n 11.100 San Fernando (SPAIN) Phone: +34 956 54 54 46 |