Date: | 2023-06-07 14:28:44 | |
Sender: | <Stefan.Riepl@bkg.bund.de> | |
Subject: | [SLR-Mail] No.2794: 7827 cable problem | |
Author: | Stefan Riepl | |
Content: | Author: Stefan Riepl Dear all, recently we noted an increased scatter in our calibration data with outliers of more than 100ps, starting from around 10th of May 2023. Investigations showed that this was due to a faulty detector signal cable. The faulty cable was replaced by a spare cable in the telescope cable wrap today (7th of July 2023). The data taken by 7827 between 10th of May and 7th of July 2023 should be looked at with care, as we can´t figure out at the moment, which passes are affected. We regret for any inconvenience. With best regards, Stefan Riepl Author: Stefan Riepl Dear all, recently we noted an increased scatter in our calibration data with outliers of more than 100ps, starting from around 10th of May 2023. Investigations showed that this was due to a faulty detector signal cable. The faulty cable was replaced by a spare cable We regret for any inconvenience. With best regards, Stefan Riepl |