Welcome >  Stations >  Riga, Latvia (1884) >  Site Log

Site Log - Riga, Latvia (1884)


      ILRS Site and System Information Form
      International Laser Ranging Service

 0.   Form

      Prepared by (Full Name)    : Kalvis Salmins
      Preparer E-mail            : kalvis.salmins@lu.lv
      Date Prepared              : 2025-02-19
      Report Type                : UPDATE
      Site Log Format Version    : 2.0
      Site Log Revision          : A


 1.   Identification of the Ranging System Reference Point (SRP)

      Site Name                  : RIGA
      IERS DOMES Number          : 12302S002
      CDP Pad ID                 : 1884
      Subnetwork                 : EUROLAS
      Description                : AZ EL INTERSECT
      Monument Description       : Concrete monolith.
      Monument Inscription       : None
      Mark Description           : brass rod survey marker
      Date Installed             : 1987-09-01
      Date Removed               : 
      Geologic Characteristic    : SAND
      Additional Information     : 


 2.   Site Location Information

      City or Town               : Riga
      State or Province          : Vidzeme
      Country                    : Latvia
      Tectonic Plate             : Eurasian
      Local Time (UTC +/- hours) : 2
      Approximate Position
        X coordinate          [m]: 3183895.6062
        Y coordinate          [m]: 1421497.3037
        Z coordinate          [m]: 5322803.9237
        Latitude            [deg]: 56.948553 N
        Longitude           [deg]: 24.059080 E
        Elevation             [m]: 31.35
      Survey Method              : GNSS CAMPAIGN, tachymetry 
      Date Measured              : 2021-01-26
      Additional Information     : ITRF 2020 2000.0


 3.   General System Information

 3.01 System Name                : Riga
      4-Character Code           : RIGL
      CDP System Number          : 44
      CDP Occupation Number      : 01
      Eccentricity to SRP (if Not Identical With SRP)
        North                 [m]: 
        East                  [m]: 
        Up                    [m]: 
        Date Measured            : 1987-09-01
      Date Installed             : 1987-09-01
      Date Removed               : 
      Additional Information     : 


 4.   Telescope Information

 4.01 Receiving Telescope Type   : CASSEGRAIN-COUDE
        Aperture              [m]: 1.0
        Mount                    : ALT-AZ
      Date Installed             : 
      Date Removed               : 
      Xmitting Telescope Type    : CASSEGRAIN-COUDE
        Aperture              [m]: 1.0
      Date Installed             : 
      Date Removed               : 
      Tracking Camera Type       : Image Amplifier + CCD/TV
        Model                    : EP-16, SK-2005
        Manufacturer             : SUN-KWANG
        Field of View       [deg]: 0.3
        Minimum Magnitude   [mag]: 11.0
      Date Installed             : 2021-01-01
      Date Removed               : 
      Transmit/Receive Path      : COMMON COUDE
      Transmit/Receive Switch    : ROTATING MIRROR
      Max Slew Rate Az    [deg/s]: 2.0
      Max Slew Rate El    [deg/s]: 2.0
      Max Used Tracking Rate Az  : 2.0
      Max Used Tracking Rate El  : 2.0
      Telescope Shelter          : ROLL-BACK ROOF
      Daylight Filter Type       : Holographic reflective notch filter
      Dayl. Filt. Bandwidth  [nm]: 0.4
      Adjustable Attenuation     : RECEIVE
      Adjustable Field of View   : 
      Transmit Efficiency        : 0.6
      Receive Efficiency         : 0.3
      Date Installed             : 1987-09-01
      Date Removed               : 2008-01-01
      Additional Information     : 

 4.02 Receiving Telescope Type   : CASSEGRAIN COUDE
        Aperture              [m]: 1.0
        Mount                    : AZ-EL
      Date Installed             : 
      Date Removed               : 
      Xmitting Telescope Type    : CASSEGRAIN COUDE
        Aperture              [m]: 1.0
      Date Installed             : 
      Date Removed               : 
      Tracking Camera Type       : Image Amplifier + CCD/TV
        Model                    : EP-16, SK-2005
        Manufacturer             : SUN-KWANG
        Field of View       [deg]: 0.3
        Minimum Magnitude   [mag]: 11.0
      Date Installed             : 
      Date Removed               : 
      Transmit/Receive Path      : COMMON COUDE
      Transmit/Receive Switch    : ROTATING MIRROR
      Max Slew Rate Az    [deg/s]: 2.0
      Max Slew Rate El    [deg/s]: 2.0
      Max Used Tracking Rate Az  : 2.0
      Max Used Tracking Rate El  : 2.0
      Telescope Shelter          : ROLL-BACK ROOF
      Daylight Filter Type       : ANDOVER interference filter
      Dayl. Filt. Bandwidth  [nm]: 0.93
      Adjustable Attenuation     : RECEIVE
      Adjustable Field of View   : 
      Transmit Efficiency        : 0.60
      Receive Efficiency         : 0.30
      Date Installed             : 2008-01-01
      Date Removed               : 2019-02-14
      Additional Information     : 

 4.03 Receiving Telescope Type   : CASSEGRAIN COUDE
        Aperture              [m]: 1.0
        Mount                    : AZ-EL
      Date Installed             : 
      Date Removed               : 
      Xmitting Telescope Type    : CASSEGRAIN COUDE
        Aperture              [m]: 1.0
      Date Installed             : 
      Date Removed               : 
      Tracking Camera Type       : EMCCD
        Model                    : IXon ULTRA 888
        Manufacturer             : Oxford
        Field of View       [deg]: 0.18
        Minimum Magnitude   [mag]: 13.0
      Date Installed             : 2019-02-14
      Date Removed               : 
      Transmit/Receive Path      : COMMON COUDE
      Transmit/Receive Switch    : ROTATING MIRROR
      Max Slew Rate Az    [deg/s]: 2.4
      Max Slew Rate El    [deg/s]: 2.4
      Max Used Tracking Rate Az  : 2.4
      Max Used Tracking Rate El  : 2.4
      Telescope Shelter          : ROLL-BACK ROOF
      Daylight Filter Type       : Spectral Filter
      Dayl. Filt. Bandwidth  [nm]: 0.15
      Adjustable Attenuation     : RECEIVE
      Adjustable Field of View   : YES: FOV 30-120
      Transmit Efficiency        : 0.3
      Receive Efficiency         : 0.3
      Date Installed             : 2019-02-14
      Date Removed               : 
      Additional Information     : 

 5.   Laser System Information

 5.01 Laser Type                 : ND:YAG
      Model                      : 
      Manufacturer               : Ekspla
      Number of Amplifiers       : 1
      Primary Wavelength     [nm]: 1064
      Primary Maximum Energy [mJ]: 280
      Secondary Wavelength   [nm]: 532
      Secondary Max. Energy  [mJ]: 120
      Xmit Energy Adjustable     : NO
        Additional Information   : 
      Pulse Width (FWHM)     [ps]: 130
      Max. Repetition Rate   [Hz]: 10
      Fullw. Beam Divergence  ["]: 4 - 40
        Theoretical Beam Div     : 
        Measured Beam Div        : 
          Method Used            : 
          Additional Information : 
      Final Beam Diameter     [m]: 0.8
      Eyesafe                    : NO
      Eyesafe Standard           : None
      Polarization on Exit       : Linear
      Laser Fire Control         : Controlled
      Laser Energy Monitor       : Continuos
      Start Diode Type           : 
        Manufactorer             : 
        Model                    : 
        Quantum Efficiency    [%]: 
        Rise/Fall Time       [ps]: 
        Date Installed           : 
        Date Removed             : 
        Signal Processing        : 
          Manufacturer           : 
          Model                  : 
          Date Installed         : 
          Date Removed           : 
          Additional Information : 
      Date Installed             : 1995-04-14
      Date Removed               : 2004-12-15
      Additional Information     : 

 5.02 Laser Type                 : ND:YAG
      Model                      : 
      Manufacturer               : 
      Number of Amplifiers       : 1
      Primary Wavelength     [nm]: 1064
      Primary Maximum Energy [mJ]: 250
      Secondary Wavelength   [nm]: 532
      Secondary Max. Energy  [mJ]: 120
      Xmit Energy Adjustable     : YES
        Additional Information   : 
      Pulse Width (FWHM)     [ps]: 150
      Max. Repetition Rate   [Hz]: 10
      Fullw. Beam Divergence  ["]: 20 - 40
        Theoretical Beam Div     : 
        Measured Beam Div        : 
          Method Used            : 
          Additional Information : 
      Final Beam Diameter     [m]: 0.85
      Eyesafe                    : NO
      Eyesafe Standard           : NONE
      Polarization on Exit       : LINEAR
      Laser Fire Control         : CONTROLLED, SYNCRONISED TO UTC
      Laser Energy Monitor       : CONTINUOUS
      Start Diode Type           : APD
        Manufactorer             : Hamamamtsu
        Model                    : C5658
        Quantum Efficiency    [%]: 16
        Rise/Fall Time       [ps]: 500
        Date Installed           : 
        Date Removed             : 
        Signal Processing        : CFD
          Manufacturer           : Tennelec
          Model                  : 454
          Date Installed         : 2004-12-15
          Date Removed           : 
          Additional Information : 
      Date Installed             : 2004-12-15
      Date Removed               : 
      Additional Information     : 


 6.   Receiver System

 6.01.01 Primary Chain
         Wavelength          [nm]: 532.0
         Detector Type           : PMT
           Manufacturer          : Russia
           Model                 : FEU-164
           Quantum Efficiency [%]: 12
           Nominal Gain          : 
           Rise Time         [ps]: 2000
           Jitter (Single PE)[ps]: 1000
           Field of View Diam ["]: 180
           Date Installed        : 1999-09-20
           Date Removed          : 2001-04-30
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : TENNELEC
           Model                 : TC-454
           Date Installed        : 2000-07-10
           Date Removed          : 2001-04-30
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : MULTI-SINGLE
           Additional Information: 
         Time of Flight Observ.  : Selective Ewent Timer
           Manufacturer          : custom made
           Model                 : SETIC-9801
           Resolution        [ps]: 10
           Precision         [ps]: 15
           Date Installed        : 1999-02-08
           Date Removed          : 2006-06-06
         Additional Information  : 

 6.01.02 Primary Chain
         Wavelength          [nm]: 532.0
         Detector Type           : PMT module
           Manufacturer          : Hamamatsu
           Model                 : H6780-20
           Quantum Efficiency [%]: 31
           Nominal Gain          : 1e7
           Rise Time         [ps]: 780
           Jitter (Single PE)[ps]: 240
           Field of View Diam ["]: 180
           Date Installed        : 2001-04-30
           Date Removed          : 
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2000-07-10
           Date Removed          : 
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Single to Multi Photons
           Additional Information: 
         Time of Flight Observ.  : Event timer
           Manufacturer          : EDI Latvia
           Model                 : RTS-2006
           Resolution        [ps]: 6
           Precision         [ps]: 10
           Date Installed        : 2006-06-06
           Date Removed          : 2016-04-28
         Additional Information  : RTS-2006 is based on Riga ET-A032

 6.01.03 Primary Chain
         Wavelength          [nm]: 532.0
         Detector Type           : PMT module
           Manufacturer          : Hamamatsu
           Model                 : H11901-20
           Quantum Efficiency [%]: 18
           Nominal Gain          : 1e7
           Rise Time         [ps]: 570
           Jitter (Single PE)[ps]: N.A.
           Field of View Diam ["]: 30 - 120
           Date Installed        : 2016-04-28
           Date Removed          : 
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2000-07-10
           Date Removed          : 2019-04-12
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Single to Multi Photons
           Additional Information: 
         Time of Flight Observ.  : Event timer
           Manufacturer          : EDI Latvia
           Model                 : RTS-2006
           Resolution        [ps]: 6
           Precision         [ps]: 10
           Date Installed        : 2006-06-06
           Date Removed          : 
         Additional Information  : RTS-2006 is based on Riga ET-A032

 6.01.04 Primary Chain
         Wavelength          [nm]: 532
         Detector Type           : PMT
           Manufacturer          : Hamamatsu
           Model                 : H11901-20
           Quantum Efficiency [%]: 15
           Nominal Gain          : 
           Rise Time         [ps]: 700
           Jitter (Single PE)[ps]: 
           Field of View Diam ["]: 30 - 120
           Date Installed        : 2019-04-12
           Date Removed          : 
         Amplifier Type          : 
           Manufacturer          : Hamamatsu
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : Leading edge
           Manufacturer          : EDI
           Model                 : TS/ATIC
           Date Installed        : 2019-04-12
           Date Removed          : 
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Multi
           Additional Information: PMT time-walk compensation is done during
                                 : post processing
         Time of Flight Observ.  : EVENT
           Manufacturer          : EDI
           Model                 : RTS 2006
           Resolution        [ps]: 8
           Precision         [ps]: 8
           Date Installed        : 
           Date Removed          : 
         Additional Information  : 
 6.02.01 Secondary Chain
         Wavelength          [nm]: 532
         Detector Type           : HPD
           Manufacturer          : PicoQuant
           Model                 : PMA-40
           Quantum Efficiency [%]: 44
           Nominal Gain          : 
           Rise Time         [ps]: 400
           Jitter (Single PE)[ps]: 
           Field of View Diam ["]: 20 - 120
           Date Installed        : 
           Date Removed          : 
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : LEADING EDGE
           Manufacturer          : EDI
           Model                 : TS/ATIC
           Date Installed        : 2019-04-12
           Date Removed          : 
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : MULTI, FEW PHOTON, SINGLE
           Additional Information: Amplifier is builtin in the detector package
         Time of Flight Observ.  : EVENT
           Manufacturer          : EDI
           Model                 : RTS-2006
           Resolution        [ps]: 8
           Precision         [ps]: 8
           Date Installed        : 2023-08-01
           Date Removed          : 
         Additional Information  : Experimental setup

 6.03.01 Tertiary Chain
         Wavelength          [nm]: 
         Detector Type           : 
           Manufacturer          : 
           Model                 : 
           Quantum Efficiency [%]: 
           Nominal Gain          : 
           Rise Time         [ps]: 
           Jitter (Single PE)[ps]: 
           Field of View Diam ["]: 
           Date Installed        : 
           Date Removed          : 
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : 
           Manufacturer          : 
           Model                 : 
           Date Installed        : 
           Date Removed          : 
           Amplitude Measurement : 
           Return-Rate Controlled: 
           Mode of Operation     : 
           Additional Information: 
         Time of Flight Observ.  : 
           Manufacturer          : 
           Model                 : 
           Resolution        [ps]: 
           Precision         [ps]: 
           Date Installed        : 
           Date Removed          : 
         Additional Information  : 


 7.   Tracking Capabilities

 7.01 Satellites
        Very Low Alt (<400 km)   : NIGHT
        Low Altitude (400-2000)  : NIGHT
        LAGEOS/LARES             : NIGHT
        GLONASS                  : NIGHT
        Etalon                   : NIGHT
        GNSS                     : NIGHT
        Geosynchronous           : NO
        Moon                     : NO
      Ave. Pass Switch Time   [s]: 300
      Average values for LAGEOS
        Single Shot RMS      [mm]: 13
        # of Obs per NP          : 20 - 300
        Use of Semi-trains       : NO
        # of Semi-train Tracks   : NO
      Range Gate Width       [ns]: 20 - 256000
      Beam Pointing Accuracy  ["]: 5
      Angle Encoder Resolution["]: N.A.
      Min. Tracking Elev.   [deg]: 15
      Laser Polarization @emitter: 
      Operation
        Months per Year          : 12
        Days per Week            : 7
        Hours per Day            : 5 - 17
        Staff per Shift          : 2 - 3
        System Shared With       : none
        Time Allocated to SLR [%]: 100
        Remotely Controllable    : NO
      Tracking Restrictions
        Go/No-go flag            : 
          Satellite Verification : 
          Date Verified          : 
        Maximum elevation        : 
          Satellite Verification : 
          Date Verified          : 
        Pass segments            : 
          Satellite Verification : 
          Date Verified          : 
        Schedule segments        : 
          Satellite Verification : 
          Date Verified          : 
        Maximum laser power limit: 
          Satellite Verification : 
        Date Verified            : 
      Date First Applicable      : 1987-09-05 HH:MM UT
      Date Last Applicable       : 2016-07-27 HH:MM UT
      Additional Information     : 

 7.02 Satellites
        Very Low Alt (<400 km)   : NIGHT
        Low Altitude (400-2000)  : NIGHT
        LAGEOS/LARES             : NIGHT
        GLONASS                  : NIGHT
        Etalon                   : NIGHT
        GNSS                     : NIGHT
        Geosynchronous           : NO
        Moon                     : NO
      Ave. Pass Switch Time   [s]: 300
      Average values for LAGEOS
        Single Shot RMS      [mm]: 12
        # of Obs per NP          : 20 - 300
        Use of Semi-trains       : NO
        # of Semi-train Tracks   : NO
      Range Gate Width       [ns]: 20 - 256000
      Beam Pointing Accuracy  ["]: 15
      Angle Encoder Resolution["]: none
      Min. Tracking Elev.   [deg]: 15
      Laser Polarization @emitter: LINEAR
      Operation
        Months per Year          : 12
        Days per Week            : 7
        Hours per Day            : 5 - 17
        Staff per Shift          : 2
        System Shared With       : R&D, Space debris, Photometry
        Time Allocated to SLR [%]: 70
        Remotely Controllable    : NO
      Tracking Restrictions
        Go/No-go flag            : NO
          Satellite Verification : 
          Date Verified          : 
        Maximum elevation        : 
          Satellite Verification : 
          Date Verified          : 
        Pass segments            : 
          Satellite Verification : 
          Date Verified          : 
        Schedule segments        : 
          Satellite Verification : 
          Date Verified          : 
        Maximum laser power limit: 
          Satellite Verification : 
        Date Verified            : 
      Date First Applicable      : 2016-07-27 HH:MM UT
      Date Last Applicable       : 
      Additional Information     : Daylight tracking currently limited to 
                                 : period before and after twilight


 8.   Calibration

 8.01 Calibration Type           : PRE+POST
      Target Location            : INTERNAL+EXTERNAL
      Target Type                : Fiber-optics cable, flat surface,CCR
      Target Structure           : METAL POLE
      Number of Targets          : 
      Target Distance(s)      [m]: 154.7120,41.730,16.399
        Date Measured            : 1998-10-15
        Accuracy             [mm]: 10
        Verification             : (multiple lines)
      Return-Rate Controlled     : NO
      Eye-Safe Method            : 
        Additional Information   : 
      Mode of Operation          : SINGLE/MULTI PHOTON
      Calibration performed      : 1
      Single Shot RMS        [mm]: 10
      Edit Criterion 1st Chain   : ITERATIVE 2.0 SIGMA
      Edit Criterion 2nd Chain   : 
      Application of Cal Data    : LINEAR FIT
      Date Installed             : 1998-10-10
      Date Removed               : 2006-07-10
      Additional Information     : 

 8.02 Calibration Type           : PRE+POST
      Target Location            : INTERNAL+EXTERNAL
      Target Type                : Fiber-optics cable, flat surface, CCR
      Target Structure           : METAL POLE
      Number of Targets          : 
      Target Distance(s)      [m]: 153.41, 41.730,
        Date Measured            : 
        Accuracy             [mm]: 10
        Verification             : internal calibration checked with external
      Return-Rate Controlled     : YES
      Eye-Safe Method            : 
        Additional Information   : 
      Mode of Operation          : SINGLE/MULTI PHOTON
      Calibration performed      : each pass
      Single Shot RMS        [mm]: 6 - 7
      Edit Criterion 1st Chain   : ITERATIVE 2.0 SIGMA
      Edit Criterion 2nd Chain   : ITERATIVE 1.0 SIGMA
      Application of Cal Data    : LINEAR FIT
      Date Installed             : 2006-07-10
      Date Removed               : 2016-05-03
      Additional Information     : 

 8.03 Calibration Type           : PRE+POST
      Target Location            : INTERNAL+EXTERNAL
      Target Type                : Fiber-optics cable, CCR
      Target Structure           : CCR at front of telescope, CONCRETE PIER
      Number of Targets          : 2
      Target Distance(s)      [m]: 25.003, 1.289
        Date Measured            : 2016-MM-DD
        Accuracy             [mm]: 2
        Verification             : internal calibration checked with external
      Return-Rate Controlled     : YES
      Eye-Safe Method            : ND FILTERS
        Additional Information   : 
      Mode of Operation          : SINGLE/MULTI PHOTON
      Calibration performed      : 120
      Single Shot RMS        [mm]: 8
      Edit Criterion 1st Chain   : ITERATIVE 2.5 SIGMA
      Edit Criterion 2nd Chain   : ITERATIVE 1.0 SIGMA
      Application of Cal Data    : LINEAR INTERPOLATION
      Date Installed             : 2016-05-03
      Date Removed               : 
      Additional Information     : 


 9.   Time and Frequency Standards

 9.01.01 Frequency Standard Type : Rubidium
         Model                   : CH1-74
         Manufacturer            : Russia
         Short Term Stab.  [e-12]: 
         Long Term Stab.   [e-12]: 
         Time Reference          : GPS
         Synchronization         : GPS
         Epoch Accuracy      [ns]: 200
         Date Installed          : 1980-01-15
         Date Removed            : 2014-02-25
         Additional Information  : 

 9.01.02 Frequency Standard Type : Rubidium disciplined by GPS
         Model                   : SecureSync 1200-033
         Manufacturer            : Spectracom
         Short Term Stab.  [e-12]: 2
         Long Term Stab.   [e-12]: 50
         Time Reference          : GPS
         Synchronization         : GPS
         Epoch Accuracy      [ns]: 30
         Date Installed          : 2014-02-25
         Date Removed            : 
         Additional Information  : 

 9.02.01 GNSS Timing Rcvr Model  : SNR-8000
         Manufacturer            : ROGUE
         Date Installed          : 1995-12-05
         Date Removed            : 2001-06-01
         Additional Information  : 

 9.02.02 GNSS Timing Rcvr Model  : 58540A
         Manufacturer            : SIMMETRICOM
         Date Installed          : 2001-06-01
         Date Removed            : 2014-02-25
         Additional Information  : 

 9.02.03 GNSS Timing Rcvr Model  : SecureSync 1200-033
         Manufacturer            : Spectracom
         Date Installed          : 2014-02-25
         Date Removed            : 
         Additional Information  : 

 9.03.01 One-way System Calibration
         Date performed          : 
         Direction Calibrated    : 
         Additional Information  : 


10.   Preprocessing Information

10.01 On-site NP Generation      : YES
      Data Screening             : Orbital & POLYNOMIAL
      Return-Rate Rejection      : 
      Edit Criterion 1st Chain   : ITERATIVE 2.5 SIGMA
      Edit Criterion 2nd Chain   : N.A.
      Upload interval            : AFTER EACH SHIFT
      Date First Applicable      : 
      Date Last Applicable       : 
      Additional Information     : 


11.   Aircraft Detection

11.01 Detection Type             : visual
      Manufacturer/Provider      : 
      Automatic Laser Shutoff    : 
      Alarms Recorded            : 
      Hazard Distance        [km]: 
      Date Installed             : 
      Date Removed               : 
      Additional Information     : 

11.02 Detection Type             : ADS-B receiver + visual
      Manufacturer/Provider      : 
      Automatic Laser Shutoff    : 
      Alarms Recorded            : 
      Hazard Distance        [km]: 
      Date Installed             : 2014-03-11
      Date Removed               : 
      Additional Information     : 


12.   Meteorological Instrumentation

12.01.01 Pressure Sensor Model   : Barometer-Paulin VBM2.
         Manufacturer            : Ericcson
         Recording Interval      : PER PASS
         Accuracy          [mbar]: 0.2
         Height Diff to SRP   [m]: 0.5
         Distance from SRP    [m]: 
         Date Installed          : 1987-09-01 HH:MM UT
         Calibration Interval    : YEARLY
         Date Removed            : 2007-03-30 HH:MM UT
         Additional Information  : 

12.01.02 Pressure Sensor Model   : BAROCAP
         Manufacturer            : VAISALA
         Recording Interval      : 10 min
         Accuracy          [mbar]: 0.5
         Height Diff to SRP   [m]: +2
         Distance from SRP    [m]: 
         Date Installed          : 2007-03-30 HH:MM UT
         Calibration Interval    : YEARLY
         Date Removed            : 2025-01-13 13:00 UT
         Additional Information  : BAROCAP belongs to WXT510 Vaisala
                                 : Weather transmitter

12.01.03 Pressure Sensor Model   : WXT-536
         Manufacturer            : Vaisala
         Recording Interval      : 10min
         Accuracy          [mbar]: 0.1
         Height Diff to SRP   [m]: -0.136
         Distance from SRP    [m]: 16
         Date Installed          : 2024-10-14 13:00 UT
         Calibration Interval    : NA
         Date Removed            : 
         Additional Information  : 
12.02.01 Temp Sensor Model       : Mercury Thermometer
         Manufacturer            : unknown
         Recording Interval      : PER PASS
         Accuracy         [deg C]: 0.2
         Date Installed          : 1987-09-01 HH:MM UT
         Calibration Interval    : YEARLY to Riga Meteo
         Date Removed            : 2007-03-30 HH:MM UT
         Additional Information  : 

12.02.02 Temp Sensor Model       : TERMOCAP
         Manufacturer            : VAISALA
         Recording Interval      : 10 min
         Accuracy         [deg C]: 0.3
         Date Installed          : 2007-03-30 HH:MM UT
         Calibration Interval    : YEARLY
         Date Removed            : 2025-01-13 13:00 UT
         Additional Information  : TERMOCAP belongs to WXT510 Vaisala
                                 : Weather transmitter

12.02.03 Temp Sensor Model       : WXT-536
         Manufacturer            : Vaisala
         Recording Interval      : 10min
         Accuracy         [deg C]: 0.3
         Date Installed          : 2024-10-14 13:00 UT
         Calibration Interval    : na
         Date Removed            : 
         Additional Information  : 
12.03.01 Humidity Sensor Model   : hair hygrometer,psychrometer
         Manufacturer            : unknown
         Recording Interval      : PER PASS
         Accuracy       [% rel h]: 15
         Date Installed          : 1987-09-01 HH:MM UT
         Calibration Interval    : MONTHLY to Riga meteo
         Date Removed            : 2007-03-30 HH:MM UT
         Additional Information  : 

12.03.02 Humidity Sensor Model   : HUMICAP180
         Manufacturer            : VAISALA
         Recording Interval      : 10 min
         Accuracy       [% rel h]: 3
         Date Installed          : 2007-03-30 HH:MM UT
         Calibration Interval    : YEARLY
         Date Removed            : 2025-01-13 13:00 UT
         Additional Information  : HUMICAP180 belongs to WXT510 Vaisala
                                 : Weather transmitter

12.03.03 Humidity Sensor Model   : WXT-536
         Manufacturer            : Vaisala
         Recording Interval      : 10 min
         Accuracy       [% rel h]: 3
         Date Installed          : 2024-10-14 13:00 UT
         Calibration Interval    : na
         Date Removed            : 
         Additional Information  : 

13.   Local Ties, Eccentricities, and Collocation Information

13.01 Collocated Permanent Geodetic Systems

13.01.01.01 GNSS                 : EUREF, IGS
            Date Installed       : 1995-12-05
            Date Removed         : 
            Additional Info      : (multiple lines)
13.01.01.02 GNSS                 : EUREF, IGS
            Date Installed       : 2013-12-11
            Date Removed         : 
            Additional Info      : 
13.01.02.01 DORIS                : NO
            Date Installed       : 
            Date Removed         : 
            Additional Info      : 
13.01.03.01 PRARE                : NO
            Date Installed       : 
            Date Removed         : 
            Additional Info      : 
13.01.04.01 VLBI                 : NO
            Date Installed       : 
            Date Removed         : 
            Additional Info      : 
13.01.05.01 Gravimeter           : No
            Date Installed       : 
            Date Removed         : 
            Additional Info      : 
13.01.06.01 Other SLR            : 
            Date Installed       : 
            Date Removed         : 
            Additional Info      : 

13.02.01.01 Local Ties from the SRP to Other Monuments or Systems on Site

         Monument Name           : Permanent GPS antenna
         Instrumentation Type    : GPS
         Instrumentation Status  : PERMANENT
         DOMES Number            : 12302M002
         CDP Number              : 
         Differential Components (ITRS)
           dx                 [m]: 3.401 +- 0.0005
           dy                 [m]: -18.661 +- 0.0004
           dz                 [m]: 6.963 +- 0.0007
           Date Measured         : 1994-01-01
           Determined by         : local GPS session
         Date Installed          : 
         Date Removed            : 
         Additional Information  : 

13.02.[0-9][0-9].[0-9][0-9] Local Ties from the SRP to Other Monuments or Systems on Site
13.02.[0-9][0-9].[0-9][0-9] Local Ties from the SRP to Other Monuments or Systems on Site
13.02.[0-9][0-9].[0-9][0-9] Local Ties from the SRP to Other Monuments or Systems on Site



         Monument Name           : 
         Monument Name           : 
         Monument Name           : GNSS antenna
         Instrumentation Type    : GNSS
         Instrumentation Type    : 
         Instrumentation Type    : GPS+GLONASS+GALILEO+BEIDOU
         Instrumentation Status  : PERMANENT
         Instrumentation Status  : 
         Instrumentation Status  : PERMANENT
         DOMES Number            : 12302M002
         DOMES Number            : 
         DOMES Number            : 12302M002
         CDP Number              : 
         CDP Number              : 
         CDP Number              : 
         Differential Components (ITRS)
         Differential Components (ITRS)
         Differential Components (ITRS)
           dx                 [m]: 
           dx                 [m]: 3.411 +- 0.0014
           dx                 [m]: 3.411 +- 0.0014
           dy                 [m]: 
           dy                 [m]: -18.673 +- 0.0014
           dy                 [m]: -18.673 +- 0.0014
           dz                 [m]: 6.951 +- 0.0026
           dz                 [m]: 
           dz                 [m]: 6.951 +- 0,0026
           Date Measured         : 2021-01-14
           Date Measured         : 
           Date Measured         : 2021-01-26
           Determined by         : 
           Determined by         : 
           Determined by         : Latvian Geospatial Information Agency 
         Date Installed          : 
         Date Installed          : 
         Date Installed          : 
         Date Removed            : 
         Date Removed            : 
         Date Removed            : 
         Additional Information  : 
         Additional Information  : 
         Additional Information  : 
         Additional Information  : 
         Additional Information  : 
         Additional Information  : 
         Additional Information  : 
         Additional Information  : 
         Additional Information  : 
13.02.[0-9][0-9].[0-9][0-9] Local Ties from the SRP to Other Monuments or Systems on Site

         Monument Name           : M1884
         Instrumentation Type    : NONE
         Instrumentation Status  : MOBILE
         DOMES Number            : 12302M001
         CDP Number              : 7560
         Differential Components (ITRS)
           dx                 [m]: 18.2429 +- 0.0006
           dy                 [m]: -23.4994 +- 0.0021
           dz                 [m]: -6.9677 +- 0.0016
           Date Measured         : 2021-01-26
           Determined by         : Latvian Geospatial Information Agency
         Date Installed          : 
         Date Removed            : 
         Additional Information  : 
13.03.01.01 Eccentricities Between Other Monuments on Site

         From: Monument Name     : Mobile laser platform
               DOMES Number      : 12302M001
               CDP Number        : 7560
         To:   Monument Name     : GPS antenna
               DOMES Number      : 12302M002
               CDP Number        : 
         Differential Components (ITRS)
           dx                 [m]: -14.837 +- 0.0004
           dy                 [m]: 4.831 +- 0.0003
           dz                 [m]: 13.913 +- 0.0007
           Date Measured         : 1994-01-01
           Determined by         : local GPS Session
         Additional Information  : 

13.03.[0-9][0-9].[0-9][0-9] Eccentricities Between Other Monuments on Site

         From: Monument Name     : M1884, Mobile laser platform
               DOMES Number      : 12302M001
               CDP Number        : 7560
         To:   Monument Name     : GNNS antenna
               DOMES Number      : 12302M002
               CDP Number        : 
         Differential Components (ITRS)
           dx                 [m]: -14.8331 +- 0.0013
           dy                 [m]: 4.8273 +- 0.009
           dz                 [m]: 13.9197 +- 0.0021
           Date Measured         : 2021-01-26
           Determined by         : Latvian Geospatial Information Agency
         Additional Information  : 


14.   Local Events Possibly Affecting Computed Position

14.01 Date                       : 
      Event                      : 
      Additional Information     : 


15.   On-Site, Point of Contact Agency Information

      Agency                     : Institute of Astronomy
                                 : University of Latvia
      Mailing Address            : Institute of Astronomy University of Latvia
                                 : Jelgavas 3, Riga, Latvia LV-1004 
      Website                    : 
      Primary Contact
        Contact Name             : Kalvis Salmins
        Telephone (primary)      : 371 26594290
        Telephone (secondary)    : 
        Fax                      : 
        E-mail                   : kalvis.salmins@lu.lv
      Secondary Contact
        Contact Name             : 
        Telephone (primary)      : 
        Telephone (secondary)    : 
        Fax                      : 
        E-mail                   : 
      Tertiary Contact
        Contact Name             : 
        Telephone (primary)      : 
        Telephone (secondary)    : 
        Fax                      : 
        E-mail                   : 
      Additional Information     : 


16.   Responsible Agency (if different from 15.)

      Agency                     : 
      Mailing Address            : 
      Primary Contact
        Contact Name             : 
        Telephone (primary)      : 
        Telephone (secondary)    : 
        Fax                      : 
        E-mail                   : 
      Secondary Contact
        Contact Name             : 
        Telephone (primary)      : 
        Telephone (secondary)    : 
        Fax                      : 
        E-mail                   : 
      Additional Information     : 


17.   More Information

      URL for More Information   : N.A.
      Hardcopy on File
        Site Map                 : NO
        Site Diagram             : NO
        Horizon Mask             : NO
        Monument Description     : NO
        Site Pictures            : YES
      Additional Information     : 


Find more topics on the central web site of the Technical University of Munich: www.tum.de