SOD | Year | Day of Year |
Time of Day |
Data Impact | System | Description |
---|---|---|---|---|---|---|
78272201 | 2024 | 019 | 12:00 | 1 | 4.01 | Implemented aberration correction by active optics |
78272201 | 2023 | 319 | 12:00 | 1 | 10.01 | moved normal point processing to new computer |
78272201 | 2023 | 310 | 16:48 | 1 | 6.01.02 | raised bias voltage of detector |
78272201 | 2023 | 283 | 12:00 | 1 | 6.01.02 | Repair of event timer power supply |
78272201 | 2023 | 158 | 17:00 | 2 | 99.99.99 | replaced detector signal cable, system delay changed |
78272201 | 2020 | 115 | 09:00 | 1 | 6.01.02 | replaced event timer input and readout electronics |
78272201 | 2019 | 148 | 18:15 | 1 | 12.01.02 | Replacement of pressure sensor due to -0.25hPa offset |
78272201 | 2016 | 132 | 15:00 | 1 | 06.01.02 | Replacement of detector due to degradation |
78272201 | 2014 | 121 | 12:00 | 3 | 99.99.99 | System put into operation |
Latest Data
Tracking Statistics
Logs