Welcome >  Stations >  Kunming, China (7819) >  Station Logs

Station History Log - Kunming, China (7819)

SOD Year Day
of Year
Time
of Day
Data Impact System Description
78197821 2024 066 11:50 1 6.01.01 We replaced the gate cable from control system and the signal cable to TC454 device on Mar. 5, 2024.
78197821 2022 346 11:00 1 5.01 The laser was replaced by a new one with 532nm wavelength, more than 2mJ/pulse energy, 2000Hz max frequency and less than 50ps pulse width main parameters.
78197821 2022 304 15:00 1 6.01.01 The trigger voltage of TC454 device is adjusted from -0.366 voltage to -2.93 voltage.
78197821 2022 088 10:00 1 6.01.01 The receive optical path was modified between the C-SPAD and the receive telescope.

Find more topics on the central web site of the Technical University of Munich: www.tum.de