Welcome >  Stations >  Matera, Italy (MLRO) (7941) >  Site Log

Site Log - Matera, Italy (MLRO) (7941)


      ILRS Site and System Information Form
      International Laser Ranging Service

 0.   Form

      Prepared by (Full Name)    : Mario Siciliani de Cumis
      Preparer E-mail            : mlro@est.asi.it 
      Date Prepared              : 2025-03-10
      Report Type                : UPDATE
      Site Log Format Version    : 2.0
      Site Log Revision          : 9.0


 1.   Identification of the Ranging System Reference Point (SRP)

      Site Name                  : Matera CGS
      IERS DOMES Number          : 12734S008
      CDP Pad ID                 : 7941
      Subnetwork                 : EUROLAS
      Description                : AZ EL INTERSECT
      Monument Description       : N.A.
      Monument Inscription       : N.A.
      Mark Description           : N.A.
      Date Installed             : 2000-01-01
      Date Removed               : 
      Geologic Characteristic    : BEDROCK
      Additional Information     : 


 2.   Site Location Information

      City or Town               : Matera
      State or Province          : Basilicata
      Country                    : Italy
      Tectonic Plate             : Adriatic-African
      Local Time (UTC +/- hours) : 
      Approximate Position
        X coordinate          [m]: 4641978.864
        Y coordinate          [m]: 1393067.472
        Z coordinate          [m]: 4133249.431
        Latitude            [deg]: 40.6486 N
        Longitude           [deg]: 16.7046 E
        Elevation             [m]: 536.9
      Survey Method              : 
      Date Measured              : 
      Additional Information     : 


 3.   General System Information

 3.01 System Name                : MLRO (Matera Laser Ranging Observatory)
      4-Character Code           : MATM
      CDP System Number          : 77
      CDP Occupation Number      : 01
      Eccentricity to SRP (if Not Identical With SRP)
        North                 [m]: 
        East                  [m]: 
        Up                    [m]: 
        Date Measured            : N.A.
      Date Installed             : 2000-01-01
      Date Removed               : 
      Additional Information     : 


 4.   Telescope Information

 4.01 Receiving Telescope Type   : Cassegrain
        Aperture              [m]: 1.50
        Mount                    : AZ-EL
      Date Installed             : 
      Date Removed               : 
      Xmitting Telescope Type    : Cassegrain
        Aperture              [m]: 1.50
      Date Installed             : 
      Date Removed               : 
      Tracking Camera Type       : ICCD
        Model                    : 
        Manufacturer             : HTSI
        Field of View       [deg]: 0.016
        Minimum Magnitude   [mag]: 15
      Date Installed             : 
      Date Removed               : 
      Transmit/Receive Path      : COMMON COUDE
      Transmit/Receive Switch    : POLARIZER
      Max Slew Rate Az    [deg/s]: 20
      Max Slew Rate El    [deg/s]: 5
      Max Used Tracking Rate Az  : 20
      Max Used Tracking Rate El  : 5
      Telescope Shelter          : DOME
      Daylight Filter Type       : Interference Filter
      Dayl. Filt. Bandwidth  [nm]: 0.3
      Adjustable Attenuation     : 0 to 6 ND
      Adjustable Field of View   : 
      Transmit Efficiency        : 0.75
      Receive Efficiency         : 0.87
      Date Installed             : 2000-01-01
      Date Removed               : 
      Additional Information     : 


 5.   Laser System Information

 5.01 Laser Type                 : ND:YAG
      Model                      : 
      Manufacturer               : 
      Number of Amplifiers       : 3
      Primary Wavelength     [nm]: 1064
      Primary Maximum Energy [mJ]: 200
      Secondary Wavelength   [nm]: 532
      Secondary Max. Energy  [mJ]: 100
      Xmit Energy Adjustable     : NO
        Additional Information   : 
      Pulse Width (FWHM)     [ps]: 50
      Max. Repetition Rate   [Hz]: 10
      Fullw. Beam Divergence  ["]: 2 - 45
        Theoretical Beam Div     : 
        Measured Beam Div        : 
          Method Used            : 
          Additional Information : 
      Final Beam Diameter     [m]: 0.010
      Eyesafe                    : NO
      Eyesafe Standard           : ANSI Z 136.1-1976
      Polarization on Exit       : 
      Laser Fire Control         : 
      Laser Energy Monitor       : 
      Start Diode Type           : 
        Manufactorer             : 
        Model                    : 
        Quantum Efficiency    [%]: 
        Rise/Fall Time       [ps]: 
        Date Installed           : 
        Date Removed             : 
        Signal Processing        : 
          Manufacturer           : 
          Model                  : 
          Date Installed         : 
          Date Removed           : 
          Additional Information : 
      Date Installed             : 2000-01-01
      Date Removed               : 2007-10-30
      Additional Information     : 

 5.02 Laser Type                 : ND:YAG
      Model                      : 
      Manufacturer               : continuum
      Number of Amplifiers       : 3
      Primary Wavelength     [nm]: 1064
      Primary Maximum Energy [mJ]: 200
      Secondary Wavelength   [nm]: 532
      Secondary Max. Energy  [mJ]: 100
      Xmit Energy Adjustable     : NO
        Additional Information   : 
      Pulse Width (FWHM)     [ps]: 50
      Max. Repetition Rate   [Hz]: 10
      Fullw. Beam Divergence  ["]: 2 - 45
        Theoretical Beam Div     : 
        Measured Beam Div        : 
          Method Used            : 
          Additional Information : 
      Final Beam Diameter     [m]: 1.5
      Eyesafe                    : NO
      Eyesafe Standard           : ANSI Z 136.1-1976
      Polarization on Exit       : 
      Laser Fire Control         : 
      Laser Energy Monitor       : 
      Start Diode Type           : 
        Manufactorer             : 
        Model                    : 
        Quantum Efficiency    [%]: 
        Rise/Fall Time       [ps]: 
        Date Installed           : 
        Date Removed             : 
        Signal Processing        : 
          Manufacturer           : 
          Model                  : 
          Date Installed         : 
          Date Removed           : 
          Additional Information : 
      Date Installed             : 2007-11-05
      Date Removed               : 2024-10-24
      Additional Information     : 

 5.03 Laser Type                 : ND:YAG
      Model                      : 
      Manufacturer               : Innolas
      Number of Amplifiers       : 2
      Primary Wavelength     [nm]: 1064
      Primary Maximum Energy [mJ]: 200
      Secondary Wavelength   [nm]: 532
      Secondary Max. Energy  [mJ]: 100
      Xmit Energy Adjustable     : YES
        Additional Information   : 
      Pulse Width (FWHM)     [ps]: 50
      Max. Repetition Rate   [Hz]: 10
      Fullw. Beam Divergence  ["]: 2 - 45
        Theoretical Beam Div     : 
        Measured Beam Div        : 
          Method Used            : 
          Additional Information : 
      Final Beam Diameter     [m]: 1.5
      Eyesafe                    : NO
      Eyesafe Standard           : ANSI Z 136.1-1976
      Polarization on Exit       : circular
      Laser Fire Control         : 
      Laser Energy Monitor       : continuous
      Start Diode Type           : 
        Manufactorer             : 
        Model                    : 
        Quantum Efficiency    [%]: 
        Rise/Fall Time       [ps]: 
        Date Installed           : 
        Date Removed             : 
        Signal Processing        : 
          Manufacturer           : 
          Model                  : 
          Date Installed         : 2024-10-24
          Date Removed           : 
          Additional Information : 
      Date Installed             : 
      Date Removed               : 
      Additional Information     : 

 6.   Receiver System

 6.01.01 Primary Chain
         Wavelength          [nm]: 532
         Detector Type           : MCP
           Manufacturer          : Photek
           Model                 : PMT209 s/n 11990416
           Quantum Efficiency [%]: 15
           Nominal Gain          : 1e6
           Rise Time         [ps]: 120
           Jitter (Single PE)[ps]: 30
           Field of View Diam ["]: 60
           Date Installed        : 2000-01-01
           Date Removed          : 2005-10-20
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2000-01-01
           Date Removed          : 
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Multi photons
           Additional Information: 
         Time of Flight Observ.  : EVENT
           Manufacturer          : HTSI
           Model                 : 
           Resolution        [ps]: 1
           Precision         [ps]: 2
           Date Installed        : 2000-01-01
           Date Removed          : 
         Additional Information  : The amplitude measurements are made 
                                 : using a Peak Amplitude Detector 
                                 : manufactured by Honeywell Technology 

 6.01.02 Primary Chain
         Wavelength          [nm]: 532
         Detector Type           : MCP
           Manufacturer          : Photek
           Model                 : PMT209 s/n 23990701
           Quantum Efficiency [%]: 12.59
           Nominal Gain          : 1e6
           Rise Time         [ps]: 120
           Jitter (Single PE)[ps]: 30
           Field of View Diam ["]: 60
           Date Installed        : 2005-10-20
           Date Removed          : 2007-02-19
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2000-01-01
           Date Removed          : 
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Multi photons
           Additional Information: 
         Time of Flight Observ.  : EVENT
           Manufacturer          : HTSI
           Model                 : 
           Resolution        [ps]: 1
           Precision         [ps]: 2
           Date Installed        : 2000-01-01
           Date Removed          : 
         Additional Information  : The amplitude measurements are made 
                                 : using a Peak Amplitude Detector 
                                 : manufactured by Honeywell Technology 

 6.01.03 Primary Chain
         Wavelength          [nm]: 532
         Detector Type           : MCP
           Manufacturer          : Photek
           Model                 : PMT212 s/n 23060822
           Quantum Efficiency [%]: 15
           Nominal Gain          : 1e6
           Rise Time         [ps]: 110
           Jitter (Single PE)[ps]: 30
           Field of View Diam ["]: 60
           Date Installed        : 2007-02-19
           Date Removed          : 2008-06-20
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2000-01-01
           Date Removed          : 
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Multi photons
           Additional Information: 
         Time of Flight Observ.  : EVENT
           Manufacturer          : HTSI
           Model                 : 
           Resolution        [ps]: 1
           Precision         [ps]: 2
           Date Installed        : 2000-01-01
           Date Removed          : 
         Additional Information  : The amplitude measurements are made 
                                 : using a Peak Amplitude Detector 
                                 : manufactured by Honeywell Technology 

 6.01.04 Primary Chain
         Wavelength          [nm]: 532
         Detector Type           : MCP
           Manufacturer          : Photek
           Model                 : PMT210 s/n 11970417
           Quantum Efficiency [%]: 12
           Nominal Gain          : 1e6
           Rise Time         [ps]: 150
           Jitter (Single PE)[ps]: 30
           Field of View Diam ["]: 60
           Date Installed        : 2008-06-20
           Date Removed          : 2009-09-16
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2000-01-01
           Date Removed          : 
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Multi photons
           Additional Information: 
         Time of Flight Observ.  : EVENT
           Manufacturer          : HTSI
           Model                 : 
           Resolution        [ps]: 1
           Precision         [ps]: 2
           Date Installed        : 2000-01-01
           Date Removed          : 
         Additional Information  : The amplitude measurements are made 
                                 : using a Peak Amplitude Detector 
                                 : manufactured by Honeywell Technology 

 6.01.05 Primary Chain
         Wavelength          [nm]: 532
         Detector Type           : MCP
           Manufacturer          : Photek
           Model                 : PMT210 s/n 21081104
           Quantum Efficiency [%]: 11.83
           Nominal Gain          : 1e6
           Rise Time         [ps]: 98
           Jitter (Single PE)[ps]: 30
           Field of View Diam ["]: 60
           Date Installed        : 2009-09-16
           Date Removed          : 2010-05-24
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2000-01-01
           Date Removed          : 
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Multi photons
           Additional Information: 
         Time of Flight Observ.  : EVENT
           Manufacturer          : HTSI
           Model                 : 
           Resolution        [ps]: 1
           Precision         [ps]: 2
           Date Installed        : 2000-01-01
           Date Removed          : 
         Additional Information  : The amplitude measurements are made 
                                 : using a Peak Amplitude Detector 
                                 : manufactured by Honeywell Technology

 6.01.06 Primary Chain
         Wavelength          [nm]: 532
         Detector Type           : MCP
           Manufacturer          : Photek
           Model                 : PMT210 s/n 11990416
           Quantum Efficiency [%]: 15
           Nominal Gain          : 1e6
           Rise Time         [ps]: 120
           Jitter (Single PE)[ps]: 30
           Field of View Diam ["]: 60
           Date Installed        : 2010-05-25
           Date Removed          : 2012-10-06
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2000-01-01
           Date Removed          : 
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Multi photons
           Additional Information: 
         Time of Flight Observ.  : EVENT
           Manufacturer          : HTSI
           Model                 : 
           Resolution        [ps]: 1
           Precision         [ps]: 2
           Date Installed        : 2000-01-01
           Date Removed          : 
         Additional Information  : The amplitude measurements are made 
                                 : using a Peak Amplitude Detector 
                                 : manufactured by Honeywell Technology

 6.01.07 Primary Chain
         Wavelength          [nm]: 532
         Detector Type           : MCP
           Manufacturer          : Photek
           Model                 : PMT210 s/n B2120502
           Quantum Efficiency [%]: 13
           Nominal Gain          : 1e6
           Rise Time         [ps]: 120
           Jitter (Single PE)[ps]: 30
           Field of View Diam ["]: 60
           Date Installed        : 2012-10-06
           Date Removed          : 2014-03-21
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2000-01-01
           Date Removed          : 
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Multi photons
           Additional Information: 
         Time of Flight Observ.  : EVENT
           Manufacturer          : HTSI
           Model                 : 
           Resolution        [ps]: 1
           Precision         [ps]: 2
           Date Installed        : 2000-01-01
           Date Removed          : 
         Additional Information  : The amplitude measurements are made 
                                 : using a Peak Amplitude Detector 
                                 : manufactured by Honeywell Technology

 6.01.08 Primary Chain
         Wavelength          [nm]: 532
         Detector Type           : MCP
           Manufacturer          : Photek
           Model                 : PMT210 s/n 41131107
           Quantum Efficiency [%]: 13
           Nominal Gain          : 1e6
           Rise Time         [ps]: 120
           Jitter (Single PE)[ps]: 30
           Field of View Diam ["]: 60
           Date Installed        : 2014-03-21
           Date Removed          : 2014-07-23
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2000-01-01
           Date Removed          : 2023-02-10
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Multi photons
           Additional Information: 
         Time of Flight Observ.  : EVENT
           Manufacturer          : HTSI
           Model                 : 
           Resolution        [ps]: 1
           Precision         [ps]: 2
           Date Installed        : 2000-01-01
           Date Removed          : 
         Additional Information  : The amplitude measurements are made 
                                 : using a Peak Amplitude Detector 
                                 : manufactured by Honeywell Technology

 6.01.09 Primary Chain
         Wavelength          [nm]: 532
         Detector Type           : MCP
           Manufacturer          : Hamamatsu
           Model                 : R5916U s/n BT0149
           Quantum Efficiency [%]: 9
           Nominal Gain          : 1e5
           Rise Time         [ps]: 120
           Jitter (Single PE)[ps]: 90
           Field of View Diam ["]: 60
           Date Installed        : 2014-07-24
           Date Removed          : 2014-09-02
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2000-01-01
           Date Removed          : 
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Multi photons
           Additional Information: 
         Time of Flight Observ.  : EVENT
           Manufacturer          : HTSI
           Model                 : 
           Resolution        [ps]: 1
           Precision         [ps]: 2
           Date Installed        : 2000-01-01
           Date Removed          : 
         Additional Information  : The amplitude measurements are made 
                                 : using a Peak Amplitude Detector 
                                 : manufactured by Honeywell Technology

 6.01.10 Primary Chain
         Wavelength          [nm]: 532
         Detector Type           : MCP
           Manufacturer          : Photek
           Model                 : PMT210 s/n B1140709
           Quantum Efficiency [%]: 13
           Nominal Gain          : 1e6
           Rise Time         [ps]: 120
           Jitter (Single PE)[ps]: 30
           Field of View Diam ["]: 60
           Date Installed        : 2014-09-02
           Date Removed          : 2017-12-04
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2000-01-01
           Date Removed          : 
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Multi photons
           Additional Information: 
         Time of Flight Observ.  : EVENT
           Manufacturer          : HTSI
           Model                 : 
           Resolution        [ps]: 1
           Precision         [ps]: 2
           Date Installed        : 2000-01-01
           Date Removed          : 
         Additional Information  : The amplitude measurements are made 
                                 : using a Peak Amplitude Detector 
                                 : manufactured by Honeywell Technology

 6.01.11 Primary Chain
         Wavelength          [nm]: 532
         Detector Type           : MCP
           Manufacturer          : Hamamatsu
           Model                 : C13068 s/n MP1501-0003
           Quantum Efficiency [%]: 40
           Nominal Gain          : 6e5
           Rise Time         [ps]: 167
           Jitter (Single PE)[ps]: 35
           Field of View Diam ["]: 60
           Date Installed        : 2017-12-04
           Date Removed          : 2022-02-14
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2000-01-01
           Date Removed          : 
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Multi photons
           Additional Information: 
         Time of Flight Observ.  : EVENT
           Manufacturer          : HTSI
           Model                 : 
           Resolution        [ps]: 1
           Precision         [ps]: 2
           Date Installed        : 2000-01-01
           Date Removed          : 
         Additional Information  : The amplitude measurements are made 
                                 : using a Peak Amplitude Detector 
                                 : manufactured by Honeywell Technology

 6.01.12 Primary Chain
         Wavelength          [nm]: 532
         Detector Type           : MCP
           Manufacturer          : Hamamatsu
           Model                 : C13068 s/n MP1812-0005
           Quantum Efficiency [%]: 40
           Nominal Gain          : 6e5
           Rise Time         [ps]: 167
           Jitter (Single PE)[ps]: 35
           Field of View Diam ["]: 60
           Date Installed        : 2022-02-14
           Date Removed          : 
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tellenec
           Model                 : TC454
           Date Installed        : 2000-01-01
           Date Removed          : 
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Multi photons
           Additional Information: 
         Time of Flight Observ.  : Event
           Manufacturer          : HTSI
           Model                 : 
           Resolution        [ps]: 1
           Precision         [ps]: 2
           Date Installed        : 2000-01-01
           Date Removed          : 
         Additional Information  : The amplitude measurements are made 
                                 : using a Peak Amplitude Detector 
                                 : manufactured by Honeywell Technology

 6.01.13 Primary Chain
         Wavelength          [nm]: 532
         Detector Type           : MCP
           Manufacturer          : Photek
           Model                 : PM210 s/n B2181102
           Quantum Efficiency [%]: 13
           Nominal Gain          : 1e6
           Rise Time         [ps]: 120
           Jitter (Single PE)[ps]: 30
           Field of View Diam ["]: 60
           Date Installed        : 2023-02-10
           Date Removed          : 
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2023-02-10
           Date Removed          : 
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : Multi photon
           Additional Information: 
         Time of Flight Observ.  : Event timer
           Manufacturer          : HTSI
           Model                 : 
           Resolution        [ps]: 1
           Precision         [ps]: 2
           Date Installed        : 2000-01-01
           Date Removed          : 
         Additional Information  : The amplitude measurements are made 
                                 : using a Peak Amplitude Detector 
                                 : manufactured by Honeywell Technology

 6.02.01 Secondary Chain
         Wavelength          [nm]: 532
         Detector Type           : STREAK CAMERA  /MCP
           Manufacturer          : Hamamatsu/Photek
           Model                 : C5680-25/PMT209
           Quantum Efficiency [%]: 8
           Nominal Gain          : 1e5
           Rise Time         [ps]: 2
           Jitter (Single PE)[ps]: 
           Field of View Diam ["]: 40
           Date Installed        : 2000-01-01
           Date Removed          : 2013-07-05
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2000-01-01
           Date Removed          : 2013-07-05
           Amplitude Measurement : NO
           Return-Rate Controlled: 
           Mode of Operation     : Multi Photons
           Additional Information: 
         Time of Flight Observ.  : EVENT
           Manufacturer          : HTSI
           Model                 : 
           Resolution        [ps]: 1
           Precision         [ps]: 2
           Date Installed        : 2000-01-01
           Date Removed          : 2013-07-05
         Additional Information  : the secondary chain has two receiving path
                                 : in the two color tracking: the Streak Camera
                                 : path and the MCP path

 6.03.01 Tertiary Chain
         Wavelength          [nm]: 355
         Detector Type           : STREAK CAMERA/MCP
           Manufacturer          : Hamamatsu/Photek
           Model                 : C5680-25/PMT209
           Quantum Efficiency [%]: 14
           Nominal Gain          : 1e5
           Rise Time         [ps]: 2
           Jitter (Single PE)[ps]: 
           Field of View Diam ["]: 40
           Date Installed        : 2000-01-01
           Date Removed          : 2013-07-05
         Amplifier Type          : 
           Manufacturer          : 
           Model                 : 
           Gain                  : 
           Bandwidth             : 
           Date Installed        : 
           Date Removed          : 
           Additional Information: 
         Signal Processing       : CFD 
           Manufacturer          : Tennelec
           Model                 : TC454
           Date Installed        : 2000-01-01
           Date Removed          : 2013-07-05
           Amplitude Measurement : YES
           Return-Rate Controlled: NO
           Mode of Operation     : 
           Additional Information: 
         Time of Flight Observ.  : EVENT
           Manufacturer          : HTSI
           Model                 : 
           Resolution        [ps]: 1
           Precision         [ps]: 2
           Date Installed        : 2000-01-01
           Date Removed          : 2013-07-05
         Additional Information  : The secondary chain has two receiving path
                                 : in the two color tracking: the Streak Camera
                                 : path and the MCP path.


 7.   Tracking Capabilities

 7.01 Satellites
        Very Low Alt (<400 km)   : YES
        Low Altitude (400-2000)  : YES
        LAGEOS/LARES             : YES
        GLONASS                  : YES
        Etalon                   : YES
        GNSS                     : YES
        Geosynchronous           : 
        Moon                     : YES
      Ave. Pass Switch Time   [s]: 30
      Average values for LAGEOS
        Single Shot RMS      [mm]: 5
        # of Obs per NP          : 1000
        Use of Semi-trains       : NO
        # of Semi-train Tracks   : N.A.
      Range Gate Width       [ns]: 20 - 10000
      Beam Pointing Accuracy  ["]: 1
      Angle Encoder Resolution["]: 0.03
      Min. Tracking Elev.   [deg]: 20
      Laser Polarization @emitter: 
      Operation
        Months per Year          : 12
        Days per Week            : 7
        Hours per Day            : 24
        Staff per Shift          : 2
        System Shared With       : NOTHING
        Time Allocated to SLR [%]: 100
        Remotely Controllable    : NO
      Tracking Restrictions
        Go/No-go flag            : 
          Satellite Verification : 
          Date Verified          : 
        Maximum elevation        : 
          Satellite Verification : 
          Date Verified          : 
        Pass segments            : 
          Satellite Verification : 
          Date Verified          : 
        Schedule segments        : 
          Satellite Verification : 
          Date Verified          : 
        Maximum laser power limit: 
          Satellite Verification : 
        Date Verified            : 
      Date First Applicable      : 2000-01-01 HH:MM UT
      Date Last Applicable       : 
      Additional Information     : 


 8.   Calibration

 8.01 Calibration Type           : HOURLY
      Target Location            : INTERNAL+EXTERNAL
      Target Type                : CORNER CUBE
      Target Structure           : EXTERNAL: concrete pier; 
                                 : INTERNAL: corner cube behind the 
                                 : secondary mirror
      Number of Targets          : 2
      Target Distance(s)      [m]: 95/45
        Date Measured            : 
        Accuracy             [mm]: 2
        Verification             : Survay comparison with external target
      Return-Rate Controlled     : 
      Eye-Safe Method            : 
        Additional Information   : 2 different external ground calibration
                                 : target are currently used depending
                                 : on sun position.
                                 : Since December 2017 the "morning" GT named F
                                 : at distance of 95mt
                                 : from 00.00 to 12.00 UTC
                                 : 
                                 : Since 2000 the "afternoon" GT named C
                                 : at distance of 45mt
                                 : from 12.00 to 00.00 UTC
                                 : 
                                 : The measures on GT named B
                                 : at distance of 192mt
                                 : from 00.00 to 12.00 UTC was discontinued
                                 : on December 2017
      Mode of Operation          : MULTI PHOTON
      Calibration performed      : 1
      Single Shot RMS        [mm]: 1
      Edit Criterion 1st Chain   : ITERATIVE 3.0 SIGMA
      Edit Criterion 2nd Chain   : ITERATIVE 3.0 SIGMA
      Application of Cal Data    : AVERAGE
      Date Installed             : 2000-01-01
      Date Removed               : 
      Additional Information     : 


 9.   Time and Frequency Standards

 9.01.01 Frequency Standard Type : Cesium
         Model                   : 5061B
         Manufacturer            : HP
         Short Term Stab.  [e-12]: 10
         Long Term Stab.   [e-12]: 0.1
         Time Reference          : GPS
         Synchronization         : GPS
         Epoch Accuracy      [ns]: 100
         Date Installed          : 2000-01-01
         Date Removed            : 2005-09-05
         Additional Information  : 

 9.01.02 Frequency Standard Type : Cesium
         Model                   : CS4000
         Manufacturer            : Symmetricom
         Short Term Stab.  [e-12]: 5
         Long Term Stab.   [e-12]: 0.02
         Time Reference          : GPS
         Synchronization         : GPS
         Epoch Accuracy      [ns]: 100
         Date Installed          : 2005-09-05
         Date Removed            : 2022-07-17
         Additional Information  : 

 9.01.03 Frequency Standard Type : Passive Hydrogen Maser
         Model                   : pH Maser 1008
         Manufacturer            : T4 Science
         Short Term Stab.  [e-12]: 0.5
         Long Term Stab.   [e-12]: 0.01
         Time Reference          : GPS
         Synchronization         : GPS
         Epoch Accuracy      [ns]: 100
         Date Installed          : 2022-07-13
         Date Removed            : 
         Additional Information  : 
 9.02.01 GNSS Timing Rcvr Model  : XL-AK
         Manufacturer            : TrueTime
         Date Installed          : 2000-01-01
         Date Removed            : 2013-04-11
         Additional Information  : 

 9.02.02 GNSS Timing Rcvr Model  : LanTime 300
         Manufacturer            : Meinberg
         Date Installed          : 2013-04-11
         Date Removed            : 
         Additional Information  : 

 9.03.01 One-way System Calibration
         Date performed          : 
         Direction Calibrated    : 
         Additional Information  : 


10.   Preprocessing Information

10.01 On-site NP Generation      : YES
      Data Screening             : NUMERICAL INTEGRATION and GAUSSIAN FIT
      Return-Rate Rejection      : 
      Edit Criterion 1st Chain   : ITERATIVE 3.0 SIGMA
      Edit Criterion 2nd Chain   : ITERATIVE 3.0 SIGMA
      Upload interval            : After each pass
      Date First Applicable      : 2001-06-01 HH:MM UT
      Date Last Applicable       : 
      Additional Information     : 


11.   Aircraft Detection

11.01 Detection Type             : RADAR and ATC DATA
      Manufacturer/Provider      : 
      Automatic Laser Shutoff    : 
      Alarms Recorded            : 
      Hazard Distance        [km]: 
      Date Installed             : 2000-01-01
      Date Removed               : 
      Additional Information     : Air traffic control data.
                                 : Radar used for near aircraft.


12.   Meteorological Instrumentation

12.01.01 Pressure Sensor Model   : 1016B-01
         Manufacturer            : Paroscientific
         Recording Interval      : 1 MINUTE
         Accuracy          [mbar]: 0.1
         Height Diff to SRP   [m]: 2.4
         Distance from SRP    [m]: 
         Date Installed          : 2000-01-01 HH:MM UT
         Calibration Interval    : 1 YEAR
         Date Removed            : 
         Additional Information  : 62540

12.02.01 Temp Sensor Model       : 4470
         Manufacturer            : Qualimetrix
         Recording Interval      : EVERY 5 MINUTES
         Accuracy         [deg C]: 0.1
         Date Installed          : 2000-01-01 HH:MM UT
         Calibration Interval    : 1 YEAR
         Date Removed            : 2024-06-04 10:00 UT
         Additional Information  : 5M110

12.02.01 Temp Sensor Model       : DMA875-T
         Manufacturer            : LSI-LASTEM
         Recording Interval      : 1 MINUTE
         Accuracy         [deg C]: 0.2
         Date Installed          : 2024-06-04 10:00 UT
         Calibration Interval    : 1 YEAR
         Date Removed            : 
         Additional Information  : 23010119
12.03.01 Humidity Sensor Model   : HX92
         Manufacturer            : Omega Engineering
         Recording Interval      : EVERY 5 MINUTES
         Accuracy       [% rel h]: 2
         Date Installed          : 2000-01-01 HH:MM UT
         Calibration Interval    : EVERY FEW YEARS
         Date Removed            : 2009-04-16 08:00 UT
         Additional Information  : 

12.03.02 Humidity Sensor Model   : HD9008TR
         Manufacturer            : Delta OHM
         Recording Interval      : EVERY 5 MINUTES
         Accuracy       [% rel h]: 2
         Date Installed          : 2009-04-16 HH:MM UT
         Calibration Interval    : EVERY FEW YEARS
         Date Removed            : 2012-10-22 HH:MM UT
         Additional Information  : 

12.03.03 Humidity Sensor Model   : HX92C
         Manufacturer            : Omega Engineering
         Recording Interval      : EVERY 5 MINUTES
         Accuracy       [% rel h]: 2
         Date Installed          : 2012-10-22 HH:MM UT
         Calibration Interval    : EVERY FEW YEARS
         Date Removed            : 2024-06-04 08:00 UT
         Additional Information  : 1212245

12.03.01 Humidity Sensor Model   : DMA875
         Manufacturer            : LSI-LASTEM
         Recording Interval      : 1 MINUTE
         Accuracy       [% rel h]: 1.5
         Date Installed          : 2024-06-04 10:00 UT
         Calibration Interval    : 1 YEAR
         Date Removed            : 
         Additional Information  : 23010119

13.   Local Ties, Eccentricities, and Collocation Information

13.01 Collocated Permanent Geodetic Systems

13.01.01.01 GNSS                 : IGS+EUREF
            Date Installed       : 1991-04-16
            Date Removed         : 
            Additional Info      : 
13.01.01.02 GNSS                 : IGS+EUREF
            Date Installed       : 2001-05-08
            Date Removed         : 
            Additional Info      : 
13.01.02.01 DORIS                : NO
            Date Installed       : 
            Date Removed         : 
            Additional Info      : 
13.01.03.01 PRARE                : NO
            Date Installed       : 
            Date Removed         : 
            Additional Info      : 
13.01.04.01 VLBI                 : YES
            Date Installed       : 1990-01-01
            Date Removed         : 
            Additional Info      : 
13.01.05.01 Gravimeter           : YES
            Date Installed       : 2007-04-03
            Date Removed         : 
            Additional Info      : 
13.01.06.01 Other SLR            : 
            Date Installed       : 
            Date Removed         : 
            Additional Info      : 

13.02.01.01 Local Ties from the SRP to Other Monuments or Systems on Site

         Monument Name           : GPS reference marker "R" (MATE)
         Instrumentation Type    : GPS 
         Instrumentation Status  : PERMANENT
         DOMES Number            : 12734M008
         CDP Number              : N.A.
         Differential Components (ITRS)
           dx                 [m]: -29.157 +- 0.001
           dy                 [m]: -22.201 +- 0.001
           dz                 [m]: 37.912 +- 0.001
           Date Measured         : 2009-05-01
           Determined by         : Telespazio CGS
         Date Installed          : 1991-04-16
         Date Removed            : 
         Additional Information  : IGS/EUREF permanent station
                                 : None

13.02.02.01 Local Ties from the SRP to Other Monuments or Systems on Site

         Monument Name           : Old Laser Telescope SAO System Marker "O"
         Instrumentation Type    : SLR
         Instrumentation Status  : PERMANENT
         DOMES Number            : 12734S001
         CDP Number              : 7939
         Differential Components (ITRS)
           dx                 [m]: -13.983 +- 0.001
           dy                 [m]: 2.624 +- 0.001
           dz                 [m]: 12.951 +- 0.001
           Date Measured         : 2000-03-01
           Determined by         : Telespazio CGS
         Date Installed          : 1983-01-01
         Date Removed            : 
         Additional Information  : Intersection of the az/el axis of MATL
                                 : (Named Marker O)

13.02.03.01 Local Ties from the SRP to Other Monuments or Systems on Site

         Monument Name           : Marker "C" PAD 
         Instrumentation Type    : MOBILE SYSTEM
         Instrumentation Status  : NON PERMANENT
         DOMES Number            : 12734M004
         CDP Number              : 7541
         Differential Components (ITRS)
           dx                 [m]: 11.277 +- 0.001
           dy                 [m]: -25.007 +- 0.001
           dz                 [m]: -17.407 +- 0.001
           Date Measured         : 2009-05-01
           Determined by         : Telespazio CGS
         Date Installed          : 1985-01-01
         Date Removed            : 
         Additional Information  : 

13.02.04.01 Local Ties from the SRP to Other Monuments or Systems on Site

         Monument Name           : Marker "V" PAD 
         Instrumentation Type    : GRAVIMETER MOBILE SYSTEM
         Instrumentation Status  : NON PERMANENT
         DOMES Number            : 
         CDP Number              : 
         Differential Components (ITRS)
           dx                 [m]: -37.241 +- 0.002
           dy                 [m]: -1.420 +- 0.001
           dz                 [m]: 31.748 +- 0.002
           Date Measured         : 2009-05-01
           Determined by         : Telespazio CGS
         Date Installed          : 2008-12-02
         Date Removed            : 
         Additional Information  : 

13.02.05.01 Local Ties from the SRP to Other Monuments or Systems on Site

         Monument Name           : Marker "M1" Pier 
         Instrumentation Type    : Calibration Target C 9992
         Instrumentation Status  : PERMANENT
         DOMES Number            : 
         CDP Number              : 
         Differential Components (ITRS)
           dx                 [m]: -22.607 +- 0.001
           dy                 [m]: 38.131 +- 0.001
           dz                 [m]: 9.078 +- 0.001
           Date Measured         : 2009-05-01
           Determined by         : Telespazio CGS
         Date Installed          : 2000-01-01
         Date Removed            : 
         Additional Information  : 

13.02.06.01 Local Ties from the SRP to Other Monuments or Systems on Site

         Monument Name           : Marker "M2" Pier 
         Instrumentation Type    : Calibration Target D 9993
         Instrumentation Status  : PERMANENT
         DOMES Number            : 
         CDP Number              : 
         Differential Components (ITRS)
           dx                 [m]: 20.930 +- 0.001
           dy                 [m]: 22.317 +- 0.001
           dz                 [m]: -36.579 +- 0.001
           Date Measured         : 2009-05-01
           Determined by         : Telespazio CGS
         Date Installed          : 2000-01-01
         Date Removed            : 
         Additional Information  : 

13.02.07.01 Local Ties from the SRP to Other Monuments or Systems on Site

         Monument Name           : Marker "M3" Pier 
         Instrumentation Type    : Calibration Target E 9994
         Instrumentation Status  : PERMANENT
         DOMES Number            : 
         CDP Number              : 
         Differential Components (ITRS)
           dx                 [m]: 43.432 +- 0.001
           dy                 [m]: -54.808 +- 0.001
           dz                 [m]: -36,874 +- 0.001
           Date Measured         : 2009-05-01
           Determined by         : Telespazio CGS
         Date Installed          : 2000-01-01
         Date Removed            : 
         Additional Information  : 

13.02.08.01 Local Ties from the SRP to Other Monuments or Systems on Site

         Monument Name           : Marker "M4" Pier 
         Instrumentation Type    : Calibration Target B 9991
         Instrumentation Status  : PERMANENT
         DOMES Number            : 
         CDP Number              : 
         Differential Components (ITRS)
           dx                 [m]: -4.369 +- 0.001
           dy                 [m]: -177.740 +- 0.001
           dz                 [m]: 73.728 +- 0.001
           Date Measured         : 2009-05-01
           Determined by         : Telespazio CGS
         Date Installed          : 2000-01-01
         Date Removed            : 
         Additional Information  : 

13.02.09.01 Local Ties from the SRP to Other Monuments or Systems on Site

         Monument Name           : Marker "M5" Pier 
         Instrumentation Type    : Calibration Target F 9995
         Instrumentation Status  : PERMANENT
         DOMES Number            : 
         CDP Number              : 
         Differential Components (ITRS)
           dx                 [m]: -59.762 +- 0.001
           dy                 [m]: -19.601 +- 0.001
           dz                 [m]: 71.613 +- 0.001
           Date Measured         : 2009-05-01
           Determined by         : Telespazio CGS
         Date Installed          : 2008-12-02
         Date Removed            : 
         Additional Information  : (M5-M)

13.03.01.01 Eccentricities Between Other Monuments on Site

         From: Monument Name     : 
               DOMES Number      : 
               CDP Number        : 
         To:   Monument Name     : 
               DOMES Number      : 
               CDP Number        : 
         Differential Components (ITRS)
           dx                 [m]: 
           dy                 [m]: 
           dz                 [m]: 
           Date Measured         : 
           Determined by         : 
         Additional Information  : 


14.   Local Events Possibly Affecting Computed Position

14.01 Date                       : 
      Event                      : 
      Additional Information     : 


15.   On-Site, Point of Contact Agency Information

      Agency                     : Agenzia Spaziale Italiana
      Mailing Address            : P.O. Box 11 - Matera, Italy
                                 : 75100 Matera Italy
      Website                    : 
      Primary Contact
        Contact Name             : Siciliani de Cumis Mario
        Telephone (primary)      : ++39-0835-377509 (Institute)
        Telephone (secondary)    : 
        Fax                      : ++39-0835-339005
        E-mail                   : mario.sicilianidecumis@asi.it
      Secondary Contact
        Contact Name             : Laser Control Room
        Telephone (primary)      : ++39-0835-377542
        Telephone (secondary)    : ++39-0835-377597
        Fax                      : n.a.
        E-mail                   : mlro@est.asi.it
      Tertiary Contact
        Contact Name             : 
        Telephone (primary)      : 
        Telephone (secondary)    : 
        Fax                      : 
        E-mail                   : 
      Additional Information     : 


16.   Responsible Agency (if different from 15.)

      Agency                     : E-Geos SpA
      Mailing Address            : 
      Primary Contact
        Contact Name             : Giuseppe Nicoletti
        Telephone (primary)      : ++39-0835-377570
        Telephone (secondary)    : 
        Fax                      : 
        E-mail                   : giuseppe.nicoletti@e-geos.it
      Secondary Contact
        Contact Name             : 
        Telephone (primary)      : 
        Telephone (secondary)    : 
        Fax                      : 
        E-mail                   : 
      Additional Information     : 


17.   More Information

      URL for More Information   : http://geodaf.mt.asi.it/html/matera.html
      Hardcopy on File
        Site Map                 : YES
        Site Diagram             : YES
        Horizon Mask             : YES
        Monument Description     : YES
        Site Pictures            : YES
      Additional Information     : 


Find more topics on the central web site of the Technical University of Munich: www.tum.de