Welcome >  Data >  Normal Points (CRD) >  Dataset No. 2633428

Detail View for Normal Points (CRD) - Dataset No. 2633428

Data Information

Satellite:Luna-21 (104)
StationApache Point, NM (70459501)
Start Data Date:2021-01-17 01:07:44
End Data Date:2021-01-17 01:11:47
Creation Date:2022-01-31 22:00:00
Version:01
Observations:1
Wavelength:532.000
Incoming Date:2022-02-02 12:30:01
Incoming Filename:nasa_202202021200.npt

System Information

Status:Valid
Send Hourly NASA OC:NASA
Send Daily NASA OCNASA
Send Daily CDDIS:NASA

FTP

Daily:n.a.
Monthly:n.a.

Data

h1 CRD  1 2022  1 31 22
h2       APOL 7045 95  1  4
h3 luna21          104  104       -1 0 2
h4  1 2021  1 17  1  7 44 2021  1 17  1 11 47  1 0 0 0 1 0 2 0
c0 0     532.0 std3 lpd apd4 cesm -1.0
c1 0 lpd  Nd-YAG 1064.00 10.00 100.00 100.0 0.5 1
c2 0 apd4 APD-array 532.000 -1.00 30.5 100.0 ECL -1.0 16.00 90.0 1.4 Functional_fit
c3 0 cesm Symmetricom_5071A_GPS CS-C001 ACM_CS_PS7186H -1.0 0.0
11  4165.0000000 2.5846102363323 std3 2  242.0      6     203.8 -1.0000 -1.0000 -1.000000  19.9 0
20  4165.000  724.53 274.22   34 0
40   121.5000000 0 std3 5481 3492 -1.0000 -1.0000000 -1.00000    2.6 -1.0000 -1.0000 -1.0000 3 0 0
50 std3  203.8 -1.000 -1.000 -1.0 1
00 run.refl.shots.thresh.yield.net 210117c.r4.s05000.t01.y7.n6
00 Git commit c7ff634cddd7780055ec598e2a27c2d2022fd49e
00 ACS Git commit 078794fed35f0847109fe8f957f167fe211e871e
00 LUN Gate width 9
00 Found bad channel(s): [6, 13]...
00 I.e.: channel(s) found to be unusual performer(s); Unused in reduction.
00 Longterm offsets data not present. 0 ps used for all channels.
00 No 1st photon bias.
00 Cesium used as timebase; Clock allan deviation suggests no...
00 uncertainty inflation is needed relative to the scale of NP uncertainty.
00 Run contains inadequate or no contemporaneous ACS data.
00 Applied ACS differential correction of -0.2 +/- 4.6 [ps]...
00 to final normal point round trip time based on distributions of...
00 historic ACS differential correction estimates.
00 (NP uncertainty already adjusted to include ACS correction uncertainty)
00 Internal studies suggest no additional uncertainty inflation is needed.
h8